Commissioning Of Burners; Removal Of Transport Screw - Stanley BRANDON 80K Installation And Commissioning Instructions

Gas fired cooker
Table of Contents

Advertisement

Both burners used in the Brandon Cooker are fully
pre-mixed
burners,
operation
and
excellent
controls are fully independent for each burner.
The
following
checks
commissioning the burners.
1.
Gas Pressures & Rates
The inlet pressure at the pressure test point on the
gas train must be measured when the cooker is off
and when both burners are running.
should
be
approximately
burners are running.
Measure
the
gas
rate
operating alone.
The gas rate is dependent on the
volume
of
air
being
therefore
it
is
essential
connected when rating each burner.
fitted with a fan flue ensure the draught is between
1-1.5
mm
W.G .
when
necessary
it is possible to adjust the gas rate using
the
rate
adjustment
fig.31).
Tighten the screw to reduce the rate and
loosen
the
screw
adjustment of the rate will also create a change in
CO
.
As there is no air adjuster on the burner it is
2
essential to monitor the CO

COMMISSIONING OF BURNERS

thus
allowing
very
combustion.
The
must
be
carried
out
This pressure
20
mbar
when
on
each
burner
while
pulled
through
the
to
have
the
flue
If the cooker is
rating
the
burners.
screw
on
the
venturi
to
increase
the
rate,
when adjusting the rate.
2
2.
Ionisation Current
silent
The
ionisation
burner
measured.
lead
from
ammeter in series.
when
Commissioning Table
Inlet Pressure
CO2 Range
Ionisation Current
both
Co. Max
it
is
REMOVAL OF TRANSPORT SCREWS
Remove the hotplate and boiler top plate.
venturi,
retaining screws from boiler plates.
fully
plates have remained in their correct positions and
that
no
transport.
If
ensuring that all seals are intact.
(see
the
Fig 31
23
current
for
each
This is done by removing the ionisation
the
control
box
Boiler
20mbar
8.6 - 9.2
7µ Amps min
50ppm
debris
has
accumulated
Replace
boiler
top
burner
must
be
and
connecting
an
Cooker
20mbar
9.0 - 9.6
7µ Amps min
50ppm
Remove
Check that all
on
them
during
plate
and
hotplate
See fig. 32.
Fig.32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brandon 100k

Table of Contents