Installation of steam generator body
Switch off all power supply before installation, and check whether you have the correct model for your steam room according to table (page 5).
Do not install the generator outdoors, in wet, freezing, or corrosive places. Do not install the generator
near to inflammables such as oil paint, diluents and fuel. Be mindful of the steam pipeline and safety
valve since the high temperature of steam is dangerous in very close proximity.
The generator MUST be installed as per the orientation denoted by image (right), level and all vents on
the unit free from obstruction.
The generator MUST be installed in a dry and very well-ventilated place - minimum requirement of
1.3 cubic meter of air space is required. Never starve the unit of air as it could cause the unit to enter into
heat protection mode and could damage the unit.
The generator can be installed either on the wall or on the ground but must be well fixed. Install the
generator as close as possible to the steam room.
To install the generator on the wall, drill two small holes with diameter of 8mm on the wall and insert the expansion screws, then hang the generator on
those screws (not supplied).
To install the generator on the ground, install a frame on the site and then screw the generator into the frame.
The central function box should be installed as near to the steam generator as possible, as the length of the cable (connecting the steam generator and the
central function box) is 500mm. Only the cable provided will work with the system, do not extend the cable.
For better service and maintenance, please install the generator with the nameplate face to front and leave more than 250mm space around the generator.
08