Each first touch will 'wake up' the touch panel, which is denoted by the buttons lighting up. Function and selection
buttons will only work once lit.
Exhaust fan:
Press the Fan Button to toggle it ON/OFF. The fan operates by default for 5 minutes, which can be modified by continuously pressing 'SET' and cycling
through the interface until the 'FAN' icon/time is shown on the screen. Change the time setting by using the up and down arrows. The range is 1-60
minutes. Once the default/set time is complete, the fan will turn itself off. The default/set time will countdown on the display until it completes and it shuts
off. The control panel will remember the time set each time the fan is activated until it is powered off at the mains.
Coloured lights:
Press the Coloured Lights Button to toggle them ON/OFF. To change the colours continuously press 'SET' and cycle through the interface until the 'Coloured
Lights' icon is shown on the screen . Press the up arrow to choose the setting 'change colours automatically.' The panel screen will revert back to the home
screen and the lights will change colour automatically. To lock the lights on a specific colour, simply press the up arrow on the main interface and it cycles
through the colours.
Salt spray:
Press the Salt Spray Button to toggle it ON/OFF. The salt spray operates by default for 30 minutes, which can be modified by continuously pressing 'SET'
and cycling through the interface until the 'SALT SPRAY' icon is shown on the screen. Change the time setting by using the up and down arrows. The range
is 1-60 minutes. The default/set time will countdown on the display until it completes and it shuts off. The control panel will remember the time set each
time the salt spray is activated until it is powered off at the mains.
Temperature instructions:
Set the temperature by continuously pressing 'SET' and navigate to the temperature interface on the panel and change using the arrows. The heating
elements will not function if the steam room temperature falls below 6°C or exceeds 60°C. The interface will show –L for 6°C and –H for 60°C.