Accessories Installation: Descaling Pump System
Cautions
1. Should be installed where it's convenient to check amount of descaling liquid.
2. Should installed indoor only and installed in a dry, clean environment.
3. Should be installed vertically, around 1.5m away from the ground.
4. Should be installed where it's easy to add liquid and carry out maintenance.
5. Should be installed in a specified and isolated room where children can't reach.
6. Never install outdoors or place where the liquid can become frozen.
7. Never install where flammable, corrosive or chemicals are in close proximity.
Location
The descaling pump cannot be installed directly above or below the steam generator. It is recommended to
keep it a minimum 0.5 meter from the steam generator.
How much descaling liquid is required each time?
7.5, 10.5 and 12kW = 270ml each time
15 and 18kW = 540ml each time
Descaling pump glass bottle capacity: 1000ML each bottle, total 2 bottles.
Attention: the system will begin to pump descaling liquid into tank 5mins after generator is turned off
(approx 2 minutes of in-operation). Check amount of descaling liquid regularly.
The switch inside the central function box denotes how long descaling liquid is pumped into the generator.
www.insigniashowers.com
Last Modified: 06/05/2022
1 = 30 seconds
2 = 60 seconds
3 = 90 seconds