Download Print this page

Insignia AIO 7.5kW Installation Manual page 38

Signature12kw steam generator

Advertisement

www.insigniashowers.com
Last Modified: 06/05/2022
Aroma pump:
Press the Aroma Pump Button to toggle it ON/OFF. There are two aroma pumps connected. Aroma Pump A and Aroma Pump B, to allow two types of oil. To
change which pump dispenses oil, continuously press 'SET' and cycle through the interface until the aroma pump icon is shown then press the arrow to
change from A to B Pump or vice versa. The pump has a default operation of 5 seconds which can not be modified. It also has a cooldown time of 5 minutes.
Humidity instructions:
The default value of the humidity sensor is 60%, with a range spanning from 60%-99%. To adjust, continuously press 'SET' and cycle through the interface
until the humidity icon is shown then change the setting using the arrows. The steam generator will stop working when the humidity threshold is reached.
Working time:
The default time is 45 minutes, with the range being 1-60 minutes. To change the time, continuously press 'SET' and cycle through the interface until the
time icon is shown. Use the up and down arrows to change the time setting. The default/set time will countdown on the display until it completes and it
shuts off. The control panel will remember the time set each time the steam is activated until it is powered off at the mains.
Descaling:
Descaling time is from 0-8 hours. "0" means automatically drain immediately, "1-3H" is waiting time, then drain, "4-8H" is where the
descaling mode is activated. To activate, continuously press 'SET' and cycle through the interface until the descale icon is shown. Use
the up and down arrows to select a time between "4-8H" and after you turn off the steam generator, it will automatically pump
descaling liquid into water tank to soak for the set time. For example, if you set 6 hours, it will soak with descaling liquid for 6 hours.
When this time is complete, the steam generator will start to drain, flushing, and then power off.The descaler will be pumped in the
steam generator after the unit has been shut down (approx. 2 minutes of in-operation
).
The switch inside the central function box denotes how long descaling liquid is pumped into the generator:
1 = 30 seconds 2 = 60 seconds 3 = 90 seconds
37

Advertisement

loading

Related Products for Insignia AIO 7.5kW

This manual is also suitable for:

Aio 10.5kwAio 12kwAio 15kwAio 18kw