Accessories Installation: Door Control System
With this system, if the steam room door is opened more than one minute, the system will turn off the steam generator automatically.
The system should be installed on the external wall of the steam room.
1.
Power Adapter for the door control system
2.
Glass Door
3.
Sensor— 3A fixed part with cable , install
on the door-frame; Sensor 3B moving part,
install on the door. Make sure when the
door closed, the sensor 3A and 3B
maximum are no further than 2mm apart.
4.
Temperature Sensor
5.
Door Control Box
www.insigniashowers.com