Table 4. IBM Supervisor-1E Module LEDs (continued)
LED
System
Active
Power Management
MGMT Ethernet
ACT
Status
Green
Amber
Red
Off
Green
Amber
Green
Amber
Green
Amber
Flashing amber
Off
Flashing Green
Off
Chapter 1. Introducing the IBM c-type SAN Directors  19
Description
All environmental sensors in the
system are within operational
bounds.
At least one power supply has
failed or the power supply fan
has failed.
The temperature of the
supervisor module exceeded the
major threshold.
The slot has detected a slot ID
parity error
The supervisor is operational and
in HA active state.
The supervisor module is in HA
standby state.
There is sufficient power
available for all installed
modules.
There is insufficient power for all
installed modules.
The mgmt0 interface is
administratively active and the
supervisor is in HA active state.
The mgmt0 interface is
administratively active and the
supervisor is in the HA standby
state.
The management port link is bad
and has been disabled due to a
hardware failure.
The mgmt0 interface is
uninitialized. No signal is
detected.
Frames are being transmitted or
received by the interface.
There is no activity on the
interface.

Advertisement