IBM SAN192C-6 Installation, Service And User Manual page 111

Hide thumbs Also See for SAN192C-6:
Table of Contents

Advertisement

Scenario 1: Dual supervisor migration
About this task
To perform a nondisruptive migration from both Supervisor-1 Modules to Supervisor-4 Modules in a
switch that has both the active and standby supervisor modules installed, follow these steps:
Note :
In the following procedure, all show outputs, system messages, and image file names are displayed for
the SAN384C-6 Director Switch. The show outputs, system messages, and image file names will vary
based on the IBM c-type Director Switch selected.
Procedure
1. Use the show module command to view the active and standby supervisor modules.
switch# show module
Mod
Ports
Module-Type
---
-----
-----------------------------------
1
48
1/10 Gbps Ethernet Module
2
48
2/4/8/10/16 Gbps Advanced FC Module
3
24
40 Gbps FCoE Module
4
48
4/8/16/32 Gbps Advanced FC Module
5
0
Supervisor Module-3
6
0
Supervisor Module-3
7
34
1/10/40G IPS,2/4/8/10/16G FC Module
8
48
4/8/16/32 Gbps Advanced FC Module
10
48
2/4/8/10/16 Gbps Advanced FC Module
Mod
Sw
---
---------------
1
8.4(1)
2
8.4(1)
3
8.4(1)
4
8.4(1)
5
8.4(1)
6
8.4(1)
7
8.4(1)
8
8.4(1)
10
8.4(1)
Mod
MAC-Address(es)
---
--------------------------------------
1
84-78-ac-1b-3d-58 to 84-78-ac-1b-3d-8b
2
f4-cf-e2-7c-cd-30 to f4-cf-e2-7c-cd-33
3
04-6c-9d-32-36-aa to 04-6c-9d-32-37-1b
4
00-76-86-bf-58-23 to 00-76-86-bf-58-57
5
9c-57-ad-fd-0d-cb to 9c-57-ad-fd-0d-dd
6
e8-ed-f3-e5-9a-4d to e8-ed-f3-e5-9a-5f
7
00-da-55-a2-25-00 to 00-da-55-a2-25-0f
8
74-86-0b-33-c6-70 to 74-86-0b-33-c6-a4
10
3c-0e-23-c5-53-d0 to 3c-0e-23-c5-53-d3
Mod
Online Diag Status
---
------------------
1
Pass
2
Pass
3
Pass
4
Pass
5
Pass
6
Pass
7
Pass
8
Pass
10
Pass
Xbar
Ports
---
-----
------------------
1
0
Fabric Module 1
2
0
Fabric Module 1
3
0
Fabric Module 1
4
0
Fabric Module 1
5
0
Fabric Module 1
6
0
Fabric Module 1
Xbar
Sw
---
---------
1
NA
Hw
------
1.1
1.3
1.0
1.0
1.3
1.1
1.0
1.0
1.1
Module-Type
------------------
Hw
------
1.0
Model
-----------------
DS-X9848-480K9
DS-X9448-768K9
DS-X9824-960K9
DS-X9648-1536K9
DS-X97-SF1-K9
DS-X97-SF1-K9
DS-X9334-K9
DS-X9648-1536K9
DS-X9448-768K9
Serial-Num
----------
JAF1718AAAD
JAE1847038X
JAE19330ASN
JAE203901ZG
JAE194005JC
JAE17440HVB
JAE195004XM
JAE213101Q3
JAE180605X3
Model
Status
----------
DS-X9710-FAB1
DS-X9710-FAB1
DS-X9710-FAB1
DS-X9710-FAB1
DS-X9710-FAB1
DS-X9710-FAB1
Chapter 3. Installing the IBM c-type SAN Device  85
Status
----------
ok
ok
ok
ok
ha-standby
active *
ok
ok
ok
ok
ok
ok
ok
ok
ok

Advertisement

Table of Contents
loading

This manual is also suitable for:

San384c-6San768c-6

Table of Contents