3. After the switch has finished booting, verify that the LED operations is as follows:
• Fan module Status LED is green.
• Power supplies:
– Input OK LED is IN.
– Output Fail LED is Fault.
• Supervisor and switching modules:
– The System LED on the supervisor module is green, indicating that all chassis environmental
monitors are reporting that the system is operational. If this LED is orange or red, one or more
environmental monitor is reporting a problem.
– The Status LED on the switching modules flashes orange once, remains orange during diagnostic
boot tests, and then turns green when the module is operational (online). If the system software
cannot start up, this LED remains orange or turns red.
Note : Contact IBM Support for technical support.
4. Verify that the system software has booted and the switch has initialized without error messages. If
you cannot resolve an issue, contact your customer service representative.
5. Complete the worksheets provided in Appendix C, "Site Planning and Maintenance Records," on page
159, for future reference.
Note : A setup utility automatically launches the first time you access the switch and guides you
through the basic configuration. For instructions about how to configure the switch and check module
connectivity, see the Cisco NX-OS Fundamentals Configuration Guide or the Cisco Fundamentals
Configuration Guide for DCNM SAN..