IBM SAN192C-6 Installation, Service And User Manual page 128

Hide thumbs Also See for SAN192C-6:
Table of Contents

Advertisement

PID: DS-C9710-FAN,
NAME: "Slot 43", DESCR: "SAN384C-6 (10 Slot) Chassis Fan Module"
PID: DS-C9710-FAN,
The following is a sample output for the show interface brief command on the Supervisor-4
Module:
switch# show interface brief
---------------------------------------------------------------------------------------
Interface Vsan
Type
---------------------------------------------------------------------------------------
fc1/1
1
fc1/2
1
fc1/3
1
fc1/4
1
fc1/5
1
fc1/6
1
fc1/7
20
fc1/8
20
The following is a sample output for the show interface status command on the Supervisor-4
Module:
switch# show interface status
fc1/1 is trunking
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:01:54:7f:ee:eb:7a:00
Peer port WWN is 20:41:00:2a:6a:5b:da:80
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Admin Speed is auto max 32 Gbps
Operating Speed is 16 Gbps
Rate mode is dedicated
Port flow-control is R_RDY
Transmit B2B Credit is 500
Receive B2B Credit is 500
B2B State Change: Admin(on), Oper(up), Negotiated Value(14)
Receive data field Size is 2112
Beacon is turned off
Logical type is core
Belongs to port-channel1
Trunk vsans (admin allowed and active) (1,20-25,102)
Trunk vsans (up) (1,20)
Trunk vsans (isolated) (21-25,102)
Trunk vsans (initializing) ()
5 minutes input rate 1568 bits/sec,196 bytes/sec, 2 frames/sec
5 minutes output rate 576 bits/sec,72 bytes/sec, 5 frames/sec
5716 frames input,355028 bytes
0 discards,0 errors
0 invalid CRC/FCS,0 unknown class
0 too long,0 too short
10924 frames output,971836 bytes
0 discards,0 errors
0 input OLS,0
0 output OLS,0 LRR, 0 NOS, 0 loop inits
500 receive B2B credit remaining
500 transmit B2B credit remaining
500 low priority transmit B2B credit remaining
Last clearing of "show interface" counters : n
The following is a sample output for the show system redundancy status command on the
Supervisor-4 Module:
switch# show system redundancy status
Redundancy mode
---------------
administrative:
102  IBM Storage Networking SAN192C-6, SAN384C-6 and SAN768C-6: SAN192C-6, SAN384C-6 and
SAN768C-6 Installation, Service, and User Guide
VID: V00 ,
SN: JAF1647ADCN
VID: V00 ,
SN: JAF1647ACHH
Admin
Admin
Status
Mode
Trunk
Mode
E
on
trunking
E
on
trunking
E
on
trunking
E
on
trunking
E
on
trunking
E
on
notConnected
auto
off
up
F
off
up
LRR,0 NOS,0 loop inits
HA
SFP
Oper
Oper
Mode
Speed
(Gbps)
swl
TE
16
swl
TE
16
swl
TE
16
swl
TE
16
swl
TE
16
swl
--
--
swl
F
8
swl
F
16
Port Logical
Channel
1
core
1
core
1
core
1
core
1
core
--
--
--
edge
--
edge

Advertisement

Table of Contents
loading

This manual is also suitable for:

San384c-6San768c-6

Table of Contents