Beretta EXCLUSIVE X Installer And User Manual page 13

Hide thumbs Also See for EXCLUSIVE X:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
MENU
ENABLE ERROR HISTORY (in the fi rst two hours of
power on)
ERROR HISTORY (if two hours of functioning have been
passed)
SCREED HEATING
DEACTIVATE FUNCTION
ACTIVATE FUNCTION
FUNCTION SETTINGS
TFMIN
TFMAX
COMBUSTION MONITORING
GAS TYPE
BOILER TYPE (*)
COMBUSTION OFFSET
ACC AUTO CAL
BOILER
REMOVE BOILER
HYDRAULIC CONFIG
SYSTEM INFO
(*) BOILER TYPE: see "4.24 Combustion Control Parameters"
4
COMMISSIONING
4.1
Preliminary checks
The first ignition should be carried out by expert personnel from an authorised Technical
Assistance Service Centre. Before starting up the boiler, check:
- that the data of the supply networks (electricity, water, gas) correspond to the label data
- that the extraction pipes of the flue gases and the air suction pipes are working correctly
- that conditions for regular maintenance are guaranteed if the boiler is placed inside or
between items of furniture
- the seal of the fuel adduction system
- that the fuel flow rate corresponds to values required by the boiler
- that the fuel supply system is sized to provide the correct flow rate to the boiler, and that
it has all the safety and control devices required by current regulations
- that the circulator rotates freely because, especially after long periods of inactivity,
deposits and/or debris can prevent free rotation (see 15.4 Eventual releasing of the
circulator shaft").
4.2
Programming the boiler
- Position the system's master switch to the "on" position. The boiler display looks like this:
FRI
09/04/2021
MENU
HOT WATER TEMPERATURE
- In some cases it may be necessary to set the TIME and DATE; in this case the machine
interface request you to carry out the operation with the message "ENTER TIME AND
DATE". Navigate with the keys to set the values.
DEFAULT VALUE FACTORY
DEACTIVATE FUNCTION
0 = only heating / 1 = instantaneous with fl owswitch / 2 = instantaneous with fl owmeter /
3 = only heating + water tank with probe / 4 = only heating + water tank with thermostat
PLANT
12:17
1.3 bar
STATE
42
°C
INFO
SET
TIME & DATE
ENTER TIME AND DATE
:
12
17
09/04/2021
USE THE ARROWS TO MODIFY
MINIMUM
SET
VALUE
DEACTIVATE FUNCTION
20 °C
15 °C
35 °C
30 °C
NATURAL GAS
A
RESTORE
RESTORE
RESTORE
RESTORE
1
0
Note: it is possible to change the TIME and DATE, DAYLIGHT SAVINGS TIME settings, as
well as the LANGUAGE and the duration of the back-lighting, even afterwards by entering
the MENU from the main screen and then selecting SETTINGS.
Note: The device automatically manages the change of time from solar to daylight savings
time and vice versa.
b
Each time that the boiler is powered an automatic venting cycle is carried out lasting
4 min. To interrupt it, carry out the procedure explained in "4.3 First commissioning".
- Set the boiler to OFF
FRI
PLANT
09/04/2021
bar
MENU
1.3
42
°C
INFO
HOT WATER TEMPERATURE
- Through the REC10CH it is possible to access, using the TECHNICAL menu, a series
of parameters that can be programmed to allow you to personalise the operation of the
boiler based on the type of system. There are 3 access levels: USER, INSTALLER and
SERVICE (see "3.1 Structure of the MENU tree of the REC10CH").
- Access the parameters and set the operation according to your type of system.
4.2.1
Boiler configuration
- Select PARAMETERS.
MAXIMUM
VALUE
ACTIVATE FUNCTION
30 °C
55 °C
NATURAL GAS / LPG
A / B / C / .....
RESET
RESET
4
selecting, from REC10CH, STATE
STATE
12:17
STATE
BOILER
MAIN ZONE
SET
TECHNICAL
INSTALLATION
PARAMETERS
WEATHER COMPENSATION
RANGE RATED
CALIBRATION
INSTALLER
ENGLISH
EN
ACCESS LEVEL
SET
NOTES
VALUE
SERVICE
INSTALLER
INSTALLER: OFF state and
low temperature system
INSTALLER
INSTALLER
SERVICE
SERVICE
SERVICE
SERVICE
INSTALLER
SERVICE
SERVICE
SERVICE
INSTALLER
INSTALLER
INSTALLER
SERVICE
BOILER.
BOILER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
13

Advertisement

Table of Contents
loading

Table of Contents