Oneida Air Systems Supercell Owner's Manual

High-pressure dust collector 30/35/55 gallon
Hide thumbs Also See for Supercell:

Advertisement

Quick Links

OWNER'S MANUAL
U.S. Patent: #8393050,
#8377160, #9125535,
#D917806
READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNING LABELS BEFORE
USING THE DUST COLLECTOR.
Rev: B 20221128
Appearance may vary slightly
Supercell
Supercell
Turbo
®
High-Pressure
Dust Collector
30/35/55 Gallon
# XSK000030
# XSK000035
# XSK000055
# XSK430000
# XSK435000
# XSK455000
Doc. #ZBM000038
®

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Supercell

  • Page 1 OWNER’S MANUAL Supercell ® Supercell Turbo ® High-Pressure Dust Collector 30/35/55 Gallon # XSK000030 # XSK000035 # XSK000055 # XSK430000 U.S. Patent: #8393050, # XSK435000 #8377160, #9125535, # XSK455000 #D917806 READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNING LABELS BEFORE USING THE DUST COLLECTOR.
  • Page 3: Table Of Contents

    Table of Contents System Start-Up Information Supercell/Supercell Turbo System Specifications Wall Bracket Mounting Specifications Wall Bracket Dimensions System Dimensions with 30 Gallon Drum System Dimensions with 35 Gallon Drum System Dimensions with 55 Gallon Drum System Contents 30/35/55 Gallon Drum...
  • Page 4: System Start-Up Information

    12. ONLY use the dust collector for its intended purpose as described in this manual. DO NOT force it or an attachment to do a job for which it was not designed. Consult this owner’s manual or reach out for recommended accessories. Oneida Air Systems, Inc.
  • Page 5 13. ENSURE enough air volume is at the suction point to capture all the particulate generated. 14. NEVER make modifications without prior approval from Oneida Air Systems. Modifying the dust collector or using it differently than intended will void the warranty and may result in malfunction or mechanical failure that leads to serious personal injury or death! 15.
  • Page 6 Oneida Air Systems assumes no responsibility or liability for the suitability of any fire and/ or explosion mitigation strategy, or any items incorporated into a collector as part of an owner/operators hazard mitigation strategy.
  • Page 7 System Start-Up Information (Continued) 12. ALWAYS check your dust bin for smoldering materials before leaving the shop. 13. NEVER introduce sparks or sources of ignition into the dust collector. Sparks can be generated in several ways: a. High speed sanders, abrasive planers, saws, and edgers may strike foreign material and create a red-hot metal fragment.
  • Page 8: Supercell/Supercell Turbo System Specifications

    Overall Weight 30 Gallon: 95 lbs 35 Gallon: 95 lbs 55 Gallon: 102 lbs The Supercell requires a 20 Amp The Supercell Turbo requires that outlet receptacle to be installed by a Licensed Electrician it be installed to a 30 Amp breaker R E QU I RE D licensed electrician.
  • Page 9: Wall Bracket Mounting Specifications

    Note: The Wall Bracket (F) is universal to all Ÿ diameter Supercell systems. The Rivnuts are used only for the 14 gallon model. Cyclone Mounting Positions The Cyclone can be rotated in 90-degree increments so that the inlet is facing parallel or perpendicular to the wall.
  • Page 10: Wall Bracket Dimensions

    45-13/16" ; 1163 mm 30 Gallon with Dolly: 49-13/16" ; 1265 mm 35 Gallon: 38-1/2" ; 978 mm 35 Gallon with Dolly: 42-1/2" ; 1080 mm 55 Gallon: 49-7/8"; 1267 mm 55 Gallon with Dolly: 53-7/8"; 1368 mm Floor Oneida Air Systems...
  • Page 11: System Dimensions With 30 Gallon Drum

    System Dimensions with 30 Gallon Drum Nominal dimensions shown. Dimensions subject to slight variations in manufacturing. Allow for an additional 24" of clearance above the Motor Assembly to allow for its removal during filter replacement and other maintenance. If you purchased the Universal Drum Dolly, add an additional 4" to the height of the unit. 20"...
  • Page 12: System Dimensions With 35 Gallon Drum

    If you purchased the Universal Drum Dolly, add an additional 4" to the height of the unit. 20" Top View 508mm 23-3/4" 508mm 23-1/2" 508mm 21-9/16" 548 mm 24-1/4" 616 mm 71-7/8" 1,826 mm 47-5/8" 1210 mm 22-1/4" 565 mm 10 Oneida Air Systems...
  • Page 13: System Dimensions With 55 Gallon Drum

    System Dimensions with 55 Gallon Drum Nominal dimensions shown. Dimensions subject to slight variations in manufacturing. Allow for an additional 24" of clearance above the Motor Assembly to allow for its removal during filter replacement and other maintenance. If you purchased the Universal Drum Dolly, add an additional 4" to the height of the unit. Top View 20"...
  • Page 14: System Contents 30/35/55 Gallon Drum

    Certain components have been pre-installed.* There may be hardware leftover. Part number Part description Part number Part description BXI001501 Supercell Motor Assembly AHX000033 Tubing Assembly BXI441501 Supercell Turbo Motor Assembly G16A VRV050500 1/2" ID Clear Vinyl Tubing 1/3' FPX040001 Filter Hold Down Plate G16B AWV000050 1/2" ID Switch Valve FCS131040H 13 x 13"...
  • Page 15 FINISH: NAME: 14Ga Galv THE INFORMATION CONTAINED IN THIS FPX040001 - Filter Hold Down 14ga rev 3 DRAWING IS THE SOLE PROPERTY OF Oneida Air Systems Inc. AND SHALL SIZE TOL: PART NO. FPX040001 NOT BE USED OR DISCLOSED TO...
  • Page 16 *You will need to supply your own wall mounting hardware. Use appropriate fasteners for the wall type you are installing your system onto (e.g. lag bolts, drywall anchors, etc.). Identify where you will install the Supercell in your shop. It must mount to a reinforced wall (studs, concrete, etc.) and is designed to...
  • Page 17 Assembly Instructions (Continued) Place a mark through the Template's (G1) Mark Mark paper at each indicated crosshair (four keyway Here Here holes and one center hole), then remove the Template (G1) from the wall [FIG. 3a]. Measure 15-1/4" up from the center hole and mark a straight level line to help with the install of the Rear Support Brace (G13) [FIG.
  • Page 18 [FIG 6]. FIG. 6 Slide the Wall Bracket (F) down so that the fastener is snugly inside the smaller section of each keyhole [FIG 7]. FIG. 7 Oneida Air Systems, Inc.
  • Page 19 Assembly Instructions (Continued) Tighten these four fasteners to secure the Wall Bracket (F) to the wall [FIG. 8]. Note: If installing over drywall, avoid overtightening as it may damage the wall. FIG. 8 Fasten the Rear Support Brace (G13) to the wall using your own suitable hardware [FIG.
  • Page 20 Flange (G14) to the Wall Bracket (F) with a Flange Gasket (G3) placed between each one. Secure together using six Hex Head Bolts (G4), six Flat Washers (G5), and six Nylock Nuts (G6) [FIG. 14]. FIG. 14 Oneida Air Systems, Inc.
  • Page 21 Assembly Instructions (Continued) Secure the Rear Support Brace (G13) to the Cyclone (E) using a 2-1/2" Hex Head Bolt (G7), Flat Washer (G8), Nylon Spacer (G12), Rubber Washer (G9), and Whiz-Lock Nut (G11) as shown in [FIG 12]. Note: Ensure that the Whiz-Lock Nuts are torqued down so that the rubber washers are firmly compressed - this will prevent air leaks.
  • Page 22 (by roughly 50%). FIG. 16 Open and slide the Ring Clamp (D) over the assembly so that it rests outside the upper flange of the Cyclone (E) [FIG. 17]. FIG. 17 Oneida Air Systems, Inc.
  • Page 23 Assembly Instructions (Continued) Install the Barrel Gasket (G2) onto the rounded, bottom edge of the Motor Assembly (A). The Barrel Gasket (G2) should be oriented so that the "ribbed" side is facing downwards [FIG. 18]. FIG. 18 Using pliers, squeeze and open the Double Spring Clamp (G17) and slip it onto the shorter end of the Tubing Assembly (G16A).
  • Page 24 Clamp's cotter pin [FIG. 22]. FIG. 21 Take the Tubing Assembly (G16) and route it through the closest retaining hole located in the back corner of the Wall Bracket (F) [FIG. 23]. Either Hole FIG. 2 Oneida Air Systems, Inc.
  • Page 25 Assembly Instructions (Continued) Connect the Dust Sentry (J) to the smaller power cord on the Motor Assembly's (A) magnetic starter. The Dust Sentry (J) should be mounted in a highly visible area using adhesive strips or the Sentry's two mounting holes [FIG.
  • Page 26 • Refer to the Dust Sentry Installation Sheet for more information. infrared Dust Sentry Discharge ultrasonic Dust Sentry FIG. 27 Seal the Drum (L) closed using the provided clamp [FIG. 28]. Collar for Flex Hose Clamp FIG. 28 Oneida Air Systems, Inc.
  • Page 27 G18A FIG. 29 ONLY USE VACUUM PRESSURE RATED FLEX-HOSE AND DUCT WITH THE SUPERCELL DUST COLLECTOR.  UNDER THE SYSTEM'S HIGH SUCTION, STANDARD HOSE/PIPE MAY COLLAPSE CAUSING AFFIXED TOOLS TO BE PULLED TOWARDS THE SYSTEM, POTENTIALLY CAUSING DAMAGE AND/OR INJURY.
  • Page 28: Maintenance

    Replace the motor section and re-latch the drum clamp to 90 PSI max to blast air along the filter’s exterior pleating. around the motor section. Hold the air nozzle at a 20 degree angle and at least 2" away Oneida Air Systems, Inc.
  • Page 29 Maintenance (Continued) Emptying the Drum Cleaning out the Cyclone When first using the dust collector, check the Drum Window If the drum becomes overfilled and the cone is packed with (K1) regularly to get an idea of how often it needs to be emptied. dust: If the Drum (L) becomes overfilled, the dust will be sucked Wear a dust mask and eye protection.
  • Page 30: Troubleshooting

    2. Use the QR Code shown to download our instructions for the Testing and Replacement of the Motor Maintenance Kit. If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Ÿ Department at 1-866-387-8822 or email support@oneida-air.com.
  • Page 31 5. The antenna wire can be further extended for improved reception if still necessary. Use wire strippers to expose metal on the wire and attach an additional length. If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Ÿ...
  • Page 32: F.a.q

    Supercell dust collector be used with ports larger than 5" in diameter. How many tools can I collect from simultaneously? The Supercell and Supercell Turbo can accommodate up to three 1" to 2.5" tools at the same time or one tool with a 4" or 5" diameter port.
  • Page 33: Recommended Accessories

    Supercell 4" / 2.5" Quick-Clamp Ductwork Kit #KDZ000012 • Upgrade your Supercell dust collector to connect to multiple tools simultaneously. • Includes gated connector ports for two 4" diameter and three 2.5" diameter connections. • Features modular quick-clamp duct fittings that are highly customizable for any shop.
  • Page 34 #SDD990000 • This lightweight and low profile mobile dolly fits nearly any cylindrical waste bin. • Includes hardware for securing larger drums to the dolly. • Includes five 2" non-marking caster wheels (3 non-locking, 2 locking). Oneida Air Systems, Inc.
  • Page 35: Warranty Information

    In no event shall Oneida Air Systems’ liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.
  • Page 36 Regardless of where you purchased your system, if you have any questions or issues with missing / damaged parts, please call Oneida Air Systems first to let us help resolve your problem. We fully stand behind the quality of our product and place the utmost value on our customer’s satisfaction.