Overview SL6+
main unit
15
14
1.
Bluetooth LED
2.
RJ12 connector for optional
telephone handset
For configuration and
intercom communica-
tion. Can also be used for
external calls. Any stan-
dard analogue tone dial
telephone can be used.
3.
Reset button
• Reset all alarms.
• Terminates a phone
call in progress.
• Triggers self test.
• Activates display of
GSM signal strength.
• Triggers battery test.
4.
LED indicators
a. Mains power
b. Active alarm/battery
status
c. PSTN/GSM net call status
5.
USB Mini B PC connection
For firmware update and
configuration.
6.
RS232 PC connection
For configuration.
1
2
6
7.
Screw terminal for optional
telephone handset
For configuration and
inter-com communica-
tion.Can also be used for
external calls. Any stan-
dard analogue tone dial
telephone can be used.
8.
Slot for optional card
CANopen-Lift
(*SL6-CAN-BOARD)
9.
Connector for external
system speaker
10.
Input LED
Green LEDs on when the
input is active.
11.
Relay LED
Yellow LEDs on when the
relay is active.
12.
GND
13.
Terminals
14.
12 V Battery, 1,2 Ah
15.
Slot for GSM interface
board
3 4a 4b 4c
5 6
13
7
8
9
10
11
12
SafeLine SL6+ v.3.9.0 EN