Fallback Lms Codes - Safeline SL6 Manual

Table of Contents

Advertisement

Fallback LMS
codes

Fallback LMS codes:

Z001: PSTN: If mains power is out longer than set time (Fallback
Alarm Delay), an LMS is sent with the code Z001
Z002: When power returns and has been back for more than set
time, an LMS is sent with the code Z002.
Z003: GSM: If ASU levels are lower than limit value (5) for set time
(Fallback Alarm Delay), an LMS is sent with the code Z003.
Z004: When ASU levels are higher than limit value (5) and has been
for more than set time, an LMS is sent with the code Z004.
Z005: PSTN: If alarm drop-off fails through any of the interfaces
(e.g. no response, busy line, no P100 start tone/acknowledgement)
and Fallback is active, an LMS is sent with the code Z005.
Z006: PSTN: If alarm drop-off fails through the prioritized interface,
the unit also tries the secondary interface. If drop-off fails through
any of the interfaces (e.g. no response, busy line, no P100 start
tone/acknowledgement) and Fallback is active, an LMS is sent with
the code Z006.
Z007: GSM: If alarm drop-off fails through any of the interfaces
(e.g. no response, busy line, no P100 start tone/acknowledgement)
and Fallback is active, an LMS is sent with the code Z007.
Z008: GSM: If alarm drop-off fails through any of the interfaces
(e.g. no response, busy line, no P100 start tone/acknowledgement)
and Fallback is active, an LMS is sent with the code Z007.
Z009: If no dial tone is detected through outgoing PSTN call
attempt, call attempts are cancelled through PSTN so the unit may
try GSM immediately instead. If the call attempt is cancelled due
to missing dial tone while Fallback is active, an LMS is sent with the
code Z009.
39
SafeLine SL6+ v.3.9.0 EN

Hide quick links:

Advertisement

Table of Contents
loading