Operating; Collective Fault - Safeline SL6 Manual

Table of Contents

Advertisement

Operating

Collective fault

Activate* this relay function
in the SafeLine LYNX app or
SafeLine Pro.
A relay function combining different relay
functions in one. When function is active it is
affected by 4 failures:
1.
System failure
• Activates the relay when main power is ok
and one interface is available (PSTN has detected the line or
GSM is online).
• Deactivates when main power is not ok or no interface is
available.
2.
Battery failure
• Deactivates in case of failed battery test
• Resets by pressing the "Reset Button"
3.
Automatic emergency button check fault
• Relay activates once every day. If something is wrong with
button, an alarm is sent to the alarm receiver.
• If collective fault is programmed on an output, this is released.
• Resets when emergency button input is changed.
4.
Call retry failure
• Deactivates if the unit after programmed number of tries fails
with alarm drop-off (if Fallback is activated both interfaces
have failed).
• Resets in case of successful alarm delivery
• Resets by pressing the "Reset Button"
* SMS programming only available for SL6-GSMR and
SL6-MINI-GSMR.
33
SafeLine SL6+ v.3.9.0 EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents