LED indication
front panel
LED 1 indicates the power supply status
Continuous green
Flashing red (400/400 ms)
Continuous red
LED 2 indicates active alarm and battery condition
Light off
Rapidly flashing yellow (200/200 ms)
Flashing red (400/400 ms)
Continuous red
LED 3 indicates the phone line's status
Flashing green (100/100 ms)
Flashing green (400/400 ms)
Slowly flashing green (200/4600 ms)
Continuous green
Flashing yellow (100/100 ms)
Flashing red
(400/400 ms)
Continuous red
Reset button
Press for 3 sec
Press 3 times
Press once
Press 5 sec - release
Mains power supply OK
Battery operated, with power to the emergency light.
Battery operated, no power to the emergency light
No active alarm/battery OK.
Active alarm not reset
Battery check in progress.
Battery test failure/no battery connected
Fire mode activated.
Call connection in progress.
Telephone line connected. GSM network OK.
Call connected.
Incoming call.
PSTN: No telephone line connected.
GSM: Searching for GSM network.
No SIM card (when using GSM).
Show GSM signal strength (see table below).
Start a self test (battery + bus initialization).
Resets an active alarm. Aborts calls in progress.
SL6+ turns off.
LED
GSM signal
1 2 3
strength
= 100 %
>= 85 %
>= 70 %
>= 55 %
>= 30 %*
>= 15 %
>= 0 %
*Minimum signal strength for using GSM interface.
16
NOTE!
Refers to battery powered only!
LED1
Reset
LED3
LED2
SafeLine SL6+ v.3.9.0 EN