Connecting the
telephone line
1
Not in use
2
Output
RJ12
3
Input
4
Input
5
Output
6
Not in use
Connect the telephone line parallell in universal terminals or the
RJ-plug, see picture above. It's possible to connect up to nine SL6+
main units to the same telephone line.
In order to access the unit remotely, it needs to be assigned a unit
number. Please refer to parameter *82* in the "Parameter List" for
more information.
Phone line is connected via RJ12 or terminal A through the
following:
NOTE:
a common mode choke is required (2.2 mH) if you have an
SafeLine SL6+ with a PCB version below 1.51. You can identify the
PCB version on your SL6+ by checking the main board's 7-fi gure
number, e.g. "0175146", where the last three numbers indicates
the PCB version. If you have an SL6+ with a version number above
1.50, you may disregard this information.
14
SafeLine SL6+ v.3.9.0 EN