Wiring diagram
SL6+ main unit
Supply voltage for the SL6
must go through an all-pole
main switch in accordance
with EN81-20.
Input 1 and 2 options
None
Filter
LMS/SMS
Clear/Maintenance
Fire Mode (default input 2)
Alarm Button (default input 1)
Input 1* (confi gurable)
Input 2* (confi gurable)
Emergency bell +**
Emergency light +***
Emergency light –***
Connect the protective earth connection to the enclosure, with a
cable of at least 1,5mm².
* Input 1 and 2 are confi gurable N/O or N/C inputs with SafeLine
Pro or SafeLine LYNX. For confi guration details, se tabel to the left.
** Maximum 200 mA on the emergency bell output.
*** Maximum 500 mA on the emergency light output.
12
Phone line, RJ12
PSTN
PSTN
Bus 12 VDC
Bus GND
Bus A
Bus B
Battery +12 VDC
Battery 0 VDC
+12 VDC
Emergency bell –**
Relay 1 Common
Relay 1 N/C
Relay 1 N/O
Relay 2 Common
Relay 2 N/C
Relay 2 N/O
230 VAC L
230 VAC N
A
B
C
D
E
F