Table of contents Introduction General information Congratulations on your new “TTR” elevator alarm Safety Precautions! Installation Component list Wiring diagram -Emg. light and pictograms Mounting Wiring diagram -Extra station card Wiring diagram -Emg. bell and -light Wiring diagram -PSTN LINE (Max 9 units) Wiring diagram -Emg.
The SafeLine may only be used for its intended purpose. Note in particular that, no unauthorized changes or additions may be made inside the SafeLine or to individual components.
TTr and other alarms! General: • Telephone in machineroom must be connected to the RJ12 jack on the front of the TTR unit. • RJ12 jack next to the 14 pin connector is for the microphone, alternatively microphone and external speaker (sold separately).
EMG. LIGHT - Jumper settings With the jumpers “J8” and J9 in the position as shown left, the SafeLine TTR can supply backup power for emergency light in the lift car. The jumpers “J1”, “J2” and “J5” shall be set as shown left and shall not be changed.
GREEN PICT. Jumper settings With the jumpers “J8” and J9 in the position as shown left, the SafeLine TTR can operate pictograms according to EN 81-28 / EN 81-70. The jumpers “J1”, “J2” and “J5” shall be set as shown left and shall not be changed.
EMG. LIGHT – Jumper settings With the jumpers “J8” and J9 in the position as shown left, the SafeLine TTR can sypply backup power for emergency light in the lift car. The SafeLine TTR can also operate pictograms according to EN 81-28 / EN 81-70.
3G will not function. The SafeLine TTR can only recognize the PIN code if the code is set to “1234”, “0000”, “1111”. In some cases the code can also be deactivated. If the PIN code is set to “1234”, “0000” or if it is deactivated the SIM card can be moved from the SafeLine TTR to any of SafeLine GSM products.
WiTh TelePhone firST STeP • In order to remotely confi gure the SafeLine, the unit must fi rst be put into confi guration mode via voice communication mode. To enter voice communication mode, refer to the instructions below.
Testing the battery alarm: • Unplug the battery contact during the battery status check. • The SafeLine TTR will now emit a battery alarm and LED 2 and the battery alarm relay will be activated (if so configured). cancelling the battery test: • Switch the main voltage supply (230 V) off and back on to cancel the test.
SerVice rePair form return procedure Safeline accepts only returns which are accompanied by a completed Service form or a simular serviceform from buyer. If the product has been purchased from one of our distributors the buyer must fi rst contact the distributor concerned in each country for assistance.