Menu-Selected Functions - Cablescan 256/PC Instruction Manual

Continuity tester
Table of Contents

Advertisement

Page 24

MENU-SELECTED FUNCTIONS

The fourteen menu-selected functions are as follows:
Learn Known Good
Save Internal
Save Cartridge
Delete Internal
Delete Cartridge
Clear Memory
Set Baud Rate
These menu-selectable functions are accessed through the Menu Run key and the Up and Down
arrow keys as described above.
To select a menu function, use the following standard procedure:
1.
Press Up or Down arrow to step through the menu until the desired function or mode is
displayed.
2.
Insert the ENABLE plug if the mode is one listed in the left column above.
3.
Press Menu Run to initiate the function or mode.
Learn Known Good
This mode is used for scanning existing continuities in a sample assembly and storing them as a
program in the working memory. As a program is stored, it writes over any program currently in
the working memory. However, User Labels are maintained if they are currently loaded in
memory. Labels can be cleared before learning by first selecting the Clear Memory function.
(To save the current program, use the SAVE function, described in a later paragraph, before
using Learn Known Good.)
Save Internal
This function is used to move a wire list program from the working memory to one of the storage
locations in the internal RAM memory.
Save Cartridge
This mode is used to move a wire list program from the working memory to one of the storage
locations in the Program Cartridge.
Delete Internal
This function is used to erase a wire list program from one of the storage locations in the internal
RAM memory.
Model 256/PC Instruction Manual
Print Wire List
Print User List
Load Internal
Load Cartridge
Loop Test