Cablescan 256/PC Instruction Manual page 21

Continuity tester
Table of Contents

Advertisement

Model 256/PC Instruction Manual
FOOTSW ITCH
P R O B E
1 2 7
J 2
1 2 8
2 5 5
J 4
2 5 6
250mA/250V
3
1.
Connect assembly fixture.
2.
Load program (Figure 8).
3.
Connect wrist strap.
4.
Connect foot switch.
5. Press SEQ BUILD.
6.
Follow the display in making connections. When the From/To point that is displayed is
touched, the tone will sound - as an aid in identifying points.
7.
To bypass a step, press SEQ BUILD or foot switch.
8.
When the assembly is completed, "OK" is displayed. Press TEST to test for bypassed
circuits or shorts.
Figure 11. Simplified SEQUENTIAL BUILD Procedure
E N A B L E
6 5
6 3
6 6
6 4
1 9 3
1 9 1
1 9 4
1 9 2
CAUTION!
For continued protection against
risk of fire, replace only with
same type and rating of fuse.
4, 7
1
P R IN T E R /S E R IA L
1
J 1
2
1 2 9
J 3
1 3 0
SEQ.
RANDOM
BUILD
BUILD
5
6
ERROR
TEST
LIST
MENU
RUN
2
Page 13
RESET
MODEL 256
8

Advertisement

Table of Contents
loading