Product Holding Bin
DHB2PT-YUM Series
NOTE: During the first few hours of operation, you may notice a faint odor.
This is normal, and the odor disappears after the first few hours of use.
The bin is tested and calibrated at the factory before shipment. However,
due to temperature and climate changes during shipment, the insulation in
To revert all settings back to the original factory defaults (product times on button bars):
1. Turn the unit off.
2. Press and hold both UP and DOWN arrows.
3. Turn the unit back on and wait 5 seconds.
Turn power On/Off switch to ON position.
1
Power On/Off Switch
LED Timing Status
3
LED Timers
RED (steady) = Ready for product
RED (flashing) = Discard product
GREEN (steady) = Oldest product, use first
GREEN (flashing) = Cook more product
YELLOW (steady) = Newer product, use green first
YELLOW (flashing) = Cook more product
Printed in USA 1/09 © 2009

Initial Startup

Resetting to Factory Defaults

7

Operation

Allow 30 minutes for
heaters to reach operating
temperature. The
Temperature Display will
show temperature as unit
warms up to the operating
temperature.
4
bin can absorb moisture. The odor during the first few hours of use is from
the drying out of the insulation (moisture is driven from the insulation's
binders, a starch-like material).
4. Release UP and DOWN arrows.
NOTE: All previously saved settings are lost upon resetting the defaults!
Use with caution.
Press PAN Buttons.
2
The PAN DISPLAYS will show the
assigned product name.
If no product is assigned, the
display will be blank. Pressing the
PAN button will not activate the
timer if the display is blank.
Pressing PAN button when product
name is displayed will start timing
cycle.
When LED is steady RED, load product and press the PAN
4
button.
If only one pan is active for a
product, the LED will turn from
RED to GREEN.
If no other pan is active for
a product, the LED for the
first pan loaded will turn
from RED to GREEN.
The LED for the 2nd pan of
the same product (3rd pan,
etc.) loaded will turn from
RED to YELLOW.
An LED timer can be stopped
(cancelled) at any time by
pressing and releasing the
corresponding PAN button
quickly 3 times.
540-517revK-EN