Safety Information; Electrical Information; Installation - Prince Castle DHB2PT-YUM Series Operation Manual

Product holding bin
Table of Contents

Advertisement

Product Holding Bin
DHB2PT-YUM Series
Indicates information important to the proper operation of the unit.
Failure to observe may result in damage to the equipment and/or
severe bodily injury or death.
Model
DHB2PT-33WS
DHB2PT-33KFC
DHB2PT-46KFC
DHB2PT-33KFCCE
DHB2PT-46KFCCE
DHB2PT-33KFCCEL
DHB2PT-46KFCCEL
DHB2PT-33KFCCEN
DHB2PT-33KFCKT1
DHB2PT-33KFCKT2
DHB2PT-46KFCCEN
DHB2PT-46KFCF12
DHB2PT-46KFCCED
DHB2PT-33KFCCED
DHB2PT-46KFCCEA
A. Remove the unit from the carton and inspect for signs of damage. If there is damage to the unit:
• notify the carrier within 24 hours of delivery
• save carton and packaging materials for inspection purposes
• contact your local dealer, or if purchased directly, the Prince Castle Sales Department at 800-722-7853 or 1-630-462-8800 to arrange for a
replacement unit.
NOTE: When installing this unit, the ambient temperature at the mounting site should not exceed 100°F (37.8°C).
B. Place the bin on a counter and seal the base to the counter with food-approved sealant.
C. Plug the power cord into the bin and connect the plug into the proper electrical outlet. All connections must be in accordance with local electrical
codes and any other applicable codes.
NOTE: The electrical receptacle should be a dedicated outlet. No other equipment should be operating on the line (refrigerators, fryers, etc.).
D. Turn the power switch to ON. Allow 30 minutes for warm-up.
NOTE: If the unit is to network with other Prince Castle units, a Retro Bun Timer may be connected to any one bin in the chain. Refer to CASTLENET
COMMUNICATIONS NETWORK in this manual.
Printed in USA 1/09 © 2009

Safety Information

WARNING

Electrical Information

Volts
Hz
Watts
208
60
3200
208
60
3200
208
60
4800
220-240
50/60
4300 Max.
220-240
50/60
6400 Max.
220-240
50/60
4300 Max.
220-240
50/60
6400 Max.
220-240
50
4300
208
60
3200
208
60
3200
220-240
50
6400
208
60
4800
220-240
50/60
6400 Max.
220-240
50/60
4300 Max.
220/240
50/60
4300 Max.

Installation

Indicates information important to the operation of the unit. Failure
to observe may result in damage to the equipment.
Amps
Plug
15.4
L6-20P
15.4
L6-20P
23.1
L6-30P
17.8 Max.
IEC309
26.7 Max.
IEC309
17.8 Max.
26.7 Max.
17.8
15.4
15.4
26.7
23.1
L6-30P
26.7 Max.
IEC309
17.8 Max.
IEC309
17.8 Max.
IEC309
2
CAUTION
Agency
UL / cUL / UL Sanitation
UL / cUL / UL Sanitation
UL / cUL / UL Sanitation
CE / UL Sanitation
CE / UL Sanitation
CE / UL Sanitation
CE / UL Sanitation
CE / UL Sanitation
CE / UL Sanitation
CE / UL Sanitation
540-517revK-EN