7. Return to Service Procedure

Before returning this engine to service;
• Make sure that you correct all problems and complete all of the necessary maintenance.
• Complete the "Operational Ground Check" in this chapter.
• Specifically monitor:
o Power output (static and idle rpm)
o Fuel and oil pressure
o Cylinder and oil temperatures
72-00