9. SHUT-DOWN PROCEDURE.

a. Idle engine at approximately 800 to 900 RPM until there is a decided drop in cylinder head
temperature.
b. Move mixture control to "Idle Cut-Off".
c. After engine stops, set magneto switch at the "off" position; this will prevent after-firing.