1. EIS Inspection
A. Examine all wires connected to the EIS for correct routing, security, clamping,
deterioration, damage, wear, fraying, chafing or breaks. Replace any deteriorated,
damaged worn, frayed, chafed, or broken wires.
B. Examine the EIS for oil leaks. Identify and correct the cause.
C. Examine the EIS manifold pressure line (Figure 1) connection to the manifold pressure
port (Figure 2) for general condition and security.