Main
Sub
Error
Code
Code
Logger
0A0
○
0A5
○
0A7
○
120
○
125
○
127
○
1A0
○
1A5
○
1A7
○
820
○
8A0
○
920
○
9A0
○
13
054
○
0D4
○
154
○
1D4
○
14
07C
○
17C
○
16
E41
○
EC1
○
F41
○
FC1
○
2-1-2.
Error 2X
When a loader assembly error is detected, one of the following error codes is displayed.
ODS-D280U/ODS-D280F
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
○
0.25 sec.
Optical block assembly Ch-2B is recording data with the maxi-
mum laser output. (On side 1)
○
0.25 sec.
Optical block assembly Ch-2B detected a laser output error. (On
side 1)
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-2B. (On side 1)
○
0.25 sec.
Optical block assembly Ch-3A is recording data with the max-
imum laser output. (On side 1)
○
0.25 sec.
Optical block assembly Ch-3A detected a laser output error. (On
side 1)
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-3A. (On side 1)
○
0.25 sec.
Optical block assembly Ch-3B is recording data with the maxi-
mum laser output. (On side 1)
○
0.25 sec.
Optical block assembly Ch-3B detected a laser output error. (On
side 1)
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-3B. (On side 1)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-2A. (On side 1)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-2B. (On side 1)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-3A. (On side 1)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-3B. (On side 1)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-2A cannot be detected. (On side 1)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-2B cannot be detected. (On side 1)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-3A cannot be detected. (On side 1)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-3B cannot be detected. (On side 1)
○
0.25 sec.
Optical block assembly OP-2 cannot move to the innermost cir-
cumference of the disc. (On side 1)
○
0.25 sec.
Optical block assembly OP-3 cannot move to the innermost cir-
cumference of the disc. (On side 1)
○
0.25 sec.
The SA actuator of optical block assembly Ch-2A cannot detect
the reference position. (On side 1)
○
0.25 sec.
The SA actuator of optical block assembly Ch-2B cannot detect
the reference position. (On side 1)
○
0.25 sec.
The SA actuator of optical block assembly Ch-3A cannot detect
the reference position. (On side 1)
○
0.25 sec.
The SA actuator of optical block assembly Ch-3B cannot detect
the reference position. (On side 1)
2-4