6-4.

CHECK

This menu is used for check and operation monitoring of each device.
6-4-1.

TEMPERATURE SENSOR

This menu is used to check the temperature sensor installed in the optical drive.
Menu hierarchy
[CHECK]
[DEVICE]
[TEMPERATURE SENSOR]
Procedure
1.
Select the "TEMPERATURE SENSOR".
A confirmation window appears waiting for entry of the [SET] button.
TEMPERATURE SENSOR
CHECK START?
OK:
SET KEY
EXIT: MENU KEY
2.
Click the [SET] button.
The current temperature (unit: °C) is displayed.
ODS-D280U
TEMPERATURE SENSOR
CHECKING...OK
FPGA :52.5
[DEG]
OP0A :41.8 OP0B :42.1
OP1A :43.0 OP1B :42.4
OP2A :41.4 OP2B :40.6
OP3A :40.6 OP3B :41.3
AGAIN: SET KEY
EXIT: MENU KEY
6-4-2.

FAN MOTOR

This menu is used to check operation of the DC fan (S) and DC fan (L) installed in the unit.
Menu hierarchy
[CHECK]
[DEVICE]
[FAN MOTOR]
ODS-D280U/ODS-D280F
ODS-D280F
TEMPERATURE SENSOR
CHECKING...OK
FPGA :47.6
[DEG]
FC
:40.0
OP0A :36.7 OP0B :36.9
OP1A :35.9 OP1B :36.6
OP2A :33.9 OP2B :33.9
OP3A :33.5 OP3B :33.5
AGAIN: SET KEY
EXIT: MENU KEY