Rdm Functions - ProLights StudioCob PFC2 User Manual

150w ip65 rated full colour cob led par
Table of Contents

Advertisement

10 - RDM FUNCTIONS

The product can communicate using RDM (Remote Device Management) protocol over a DMX512
Networks.
RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open
standard for DMX512 device configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting
existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to
and receive messages from specific fixtures.
The PIDs in the following tables are supported in the product.
Category
Product
Information
DMX512
Setup
Dimmer
Settings
Sensors
Power/Lamp
Settings
Display
Settings
Control
14
Parameter
DEVICE_INFO
DEVICE_MODEL_DESCRIPTION
MANUFACTURER_LABEL
DEVICE_LABEL
FACTORY_DEFAULTS
SOFTWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_PERSONALITY_DESCRIPTION
DMX_START_ADDRESS
CURVE
CURVE_DESCRIPTION
MODULATION_FREQUENCY
MODULATION_FREQUENCY_ DESCRIPTION
SENSOR_DEFINITION
SENSOR_VALUE
DEVICE_HOURS
LAMP_HOURS
LAMP_STRIKES
DISPLAY_INVERT
IDENTIFY_DEVICE
PROLIGHTS - StudioCob PFC2
PID
GET
0x0060
x
0x0080
x
0x0081
x
0x0082
x
0x0090
x
0x00C0
x
0x00E0
x
0x00E1
x
0x00F0
x
0x0343
x
0x0344
x
0x0347
x
0x0348
x
0x0200
x
0x0201
x
0x0400
x
0x0401
x
0x0402
x
0x0500
x
0x1000
x
SET
x
x
x
x
x
x
x
x
x
x
x
x
x

Advertisement