The shielding of surrounding equipment and other cables can reduce the electromagnetic
interference. The whole welding area can be shielded for special applications.
Main technical information
1. Main technical parameter
Rated input voltage(V)
Rated input power(KVA)
Rated input current(A)
Model
No-load voltage(V)
Output current(A)
Rated Output
Rated duty cycle(%)
Efficiency(%)
Insulation grade
Protection grade
WeightKg)
Dimension
TIG-200
1PH AC220V±15%,50/60Hz
MMA
4.6
21
56V
20-130
130A/25.2V
40%
70
F
IP21
5
396*142*268
- 8 -
TIG
3.5
16
20-150
150A/16V