Display the values of each parameter;
Welding function indicator light:
5
Parameter light:
6
lamp is off to adjust the interval time;
selection button to store welding parameters and built-in parameters ; There are 9 channels
respectively, channel 0-4 store the self-tuning parameters and channel 5-8 save the Built-in
parameters;
Save Function : For example, select channel 0 in advance, adjust the corresponding
Built-in parameters in TIG welding mode:U5-D0.8,spot welding 0.8mm workpiece;
Built-in parameters in TIG interval welding mode: P5-P8, weld 0.6mm, 1.0mm, 1.5mm, 3.0mm
CLEAN,clean the color of the workpiece after argon arc welding;
TIG;
MMA;
TIG Interval,similar to automatic spot welding function;
Current light;adjust the current value under Clean and TIG mode;
Cold clean C5-C9, hot clean H10-H40 under Clean mode;
Under TIG interval mode, the lamp is on to adjust the current value, and the
Gas delay indicator;Under TIG mode,the time range of adjusting gas delay
is 0-10s;
Under TIG interval mode, gas delay time fixed in 2.5S;
Storage indicator; Under TIG、 TIG interval mode, long press the parameter
parameters,and then long press the parameter selection button to
automatically jump to the next channel, and the parameters of channel 0
will be saved;And so on;
U6-L0.8,Continuous welding 0.8mm workpiece;
U7-D3.0,spot welding 3.0mm workpiece;
U8-L3.0,Continuous welding 3.0mm workpiece;
- 15 -