Welding function indicator light:
5
Parameter light:
6
lamp is off to adjust the interval time;
Save Function : For example, select channel 0 in advance, adjust the corresponding
Built-in parameters in TIG welding mode: U5-D0.8, spot welding 0.8mm workpiece ;
Built-in parameters in TIG interval welding mode:P5-P8,weld 0.6mm,1.0mm,
1.5mm,3.0mm workpiece;
Clean,clean the color of the workpiece after argon arc welding;
TIG;
TIG Interval,similar to automatic spot welding function;
Current light;adjust the current value under Clean and TIG mode;
Cold clean C5-C9, hot clean H10-H40 under Clean mode;
Under TIG interval mode, the lamp is on to adjust the current value, and the
Gas delay indicator;Under TIG mode,the time range of adjusting gas delay
is 0-10s;
Under TIG interval mode, gas delay time fixed in 2.5S;
Storage indicator;Under TIG、TIG interval mode,long
press the parameter selection button to store welding parameters and
built-in parameters;There are 9 channels respectively, channel 0-4
store the self-tuning parameters and channel 5-8 save the Built-in
parameters;
parameters, and then long press the parameter selection button to
automatically jump to the next channel, and the parameters of channel 0
will be saved;And so on;
U6-L0.8,Continuous welding 0.8mm workpiece;
U7-D3.0,spot welding 3.0mm workpiece;
U8-L3.0,Continuous welding 3.0mm workpiece;