Installation
1. Environment
Install in a dry environment with humidity less than 90% at 20℃ and 50% at 40℃.
The temperature should be in the range of -10℃-40℃ when welding, and -20℃-55℃ for
storage and transportation.
Shelter the machine from direct sunshine and rain. Avoid raindrops.
Avoid using it in an environment with strong air flow when TIG welding.
The inclination of the welding power is less than 10
Avoid using it in a dusty, acid or other corrosive environment.
The machine should be placed more than 20cm from the wall, and more than 10cm from
other welding machines.
2. Requirement of the input power source
Waveform: standard pure sine wave
Fluctuation range: 220V 15%
Frequency: 50Hz/60Hz
3. Input power
Min. power of power grid
Input
protection
Cable
Enlarge the input , output and grounding cable according to the cable length.
Remark: the specifications of fuse and circuit breaker in the table above are only for reference.
Model
Input power
Fuse
Circuit breaker
input
output
ground
0
the altitude no more than 1000m.
TIG-200
1PH AC220V±15%,50/60Hz
7
40
63
2.5mm
16mm
2.5mm
- 9 -
2
2
2