9 Power Supply Requirement

Motor Power Supply
The calculation of the needed power for the motor supply depends on the
application and the used motor. The nominal supply voltage is 72 VDC. The
possible range is from 24 to 85 VDC.
ATTENTION: The motor supply can rise up to 95 VDC when braking. This
means that everything connected to that power supply needs a voltage
rating of 100 VDC. (Additional capacitors, etc...)
To provide short circuit power limitation, it is required to use an external fuse
(10AT for blank labeled (LC) and 16AT for HC and XC labeled controllers).
Recommended Power supplies:
Item
Description
T01-72/420
72VDC, 15A peak, 420VA, 3x400VAC
T01-72/420-US
72VDC, 15A peak, 420VA, 3x230VAC
T01-72/900
72VDC, 30A peak, 900VA, 3x400VAC
T01-72/900-US
72VDC, 30A peak, 900VA, 3x230VAC
T01-72/1500
72VDC, 2x30A peak, 1500VA, 3x400VAC
T01-72/1500-US
72VDC, 2x30A peak, 1500VA, 3x230VAC
S01-72/500
72VDC, 500W, 750W peak, 1x100..120VAC/200..240VAC
S01-72/1000
72VDC, 1000W, 2000W peak, 3x380..500VAC
Signal Power Supply
The logic supply needs a regulated power supply with a nominal voltage of 24 VDC.
The voltage must be between 22 and 26 VDC.
Current Consumption
Min. 200mA (no load on the outputs)
Typ. 0.5A
Max. 1.2A
To limit the power in case of malfunction,
it is required to use an external fuse (2AT)!
®
NTI AG / LinMot
(all 6 outputs "on" with 50mA load and /Break with no load)
(all 6 outputs "on" with 100mA load and /Break with 0.5A load)
www.LinMot.com