LinMot Installation Guide
7.3 X3
X3
Motor
DSUB-9 (f)
Note:
Use +5V (X3.3) and AGND (X3.8) only for motor internal hall sensor supply (max. 100mA). Cable length <
30m.
Caution:
Do NOT connect AGND (X3.8) to ground or earth!
It is only allowed to use X3 for connecting the motor phases if RMS current is below 2A and peak current
below 4A.
Motor Wiring for Phase Currents above 2A RMS or 4A peak (recommended general wiring)
Important:
If motor phase current exceeds 2A
®
NTI AG / LinMot
LinMot Motor:
1
Motor Phase 1+
2
Motor Phase 2+
3
+5VDC
4
Sensor Sine
5
Temp. In
6
Motor Phase 1-
7
Motor Phase 2-
8
AGND
9
Sensor Cosine
case
Shield
or 4A
RMS
www.LinMot.com
3-phase EC-Motor:
+5VDC (Hall Supply)
Hall 1
Hall 3
AGND (Hall Supply)
Hall 2
, motor phases must be wired to X2!
peak
Page 10/19