CC-Link IE Field Basic Interface Manual This document applies to the following devices: · C1250-CC-xx-xx-xxx (SG6) (with CC-Link IE Field Basic Interface SW installed) October 2019 Doc.: 0185-1171-E_1V0_MA_CC-Link_IE_Field_Basic...
Page 2
NTI AG. LinMot® is a registered trademark of NTI AG. Note The information in this documentation reflects the stage of development at the time of press and is therefore without obligation.
1 SYSTEM OVERVIEW The LinMot C1250-CC-xx-xx devices are CC-Link IE Field Basic slaves with the following parameters: Device Property Value Number of occupied stations Standard response time 1ms or less For further information on CC-Link IE Field Basic please visit: https://www.cc-link.org/en/index.html...
Station-ID Low Nibble (0 … F). Bit 1 is the LSB, bit 4 the MSB. Setting the Station-ID high & low to 0xFF initiates resetting the drive to manufacturer settings! 3 CC-LINK IE FIELD BASIC PARAMETERS AND VARIABLES NTI AG / LinMot Page 5 of 12...
The LinMot-Talk software can be downloaded from http://www.linmot.com. 3.1.1 Dis-/Enable With the Dis-/Enable parameter the LinMot device can be run without the CC-Link IE Field Basic Interface going online. So in a first step the system can be configured and run without any bus connection.
UPID of the parameter channel 5. Channel 6 UPID Defines the source variable by UPID of the parameter channel 6. Channel 7 UPID Defines the source variable by UPID of the parameter channel 7. NTI AG / LinMot Page 7 of 12...
Value Out 4 MAPPING OF PROCESS DATA The LinMot drive is a CC-Link IE Field Basic slave. To configure it with a CC-Link master, the corresponding CSP+ file is used. The CSP+ File can be found in the installation directory.
TX_Cfg_Module_Control UInt16 TX_Cfg_Module_Index_Out UInt16 TX_Cfg_Module_Value_Out UInt32 1 For a detailed description on how to use this m odule please consult the m anual “LinMot drive Configuration over Fieldbus Interfaces SG5”. 4.2 Data received from PLC Data Type Index Name Data Type...
UInt16 RX_Cfg_Module_Index_In UInt16 RX_Cfg_Module_Value_In UInt32 1 For a detailed description on how to use this m odule please consult the m anual “LinMot drive Configuration over Fieldbus Interfaces SG5”. 5 RT LEDS Error Codes RT Bus Error Description Station is disconnected.
Check if the Station-ID / IP-Address of the drive matches with the one configured in the PLC. Possible Solution: Check if the Station-ID / IP-Address of the drive is unique, and no other device in the network has the same ID. NTI AG / LinMot Page 11 of 12...