PREVOST H3-41 Manual page 104

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

TECHNICAL INFORMATION
MAIN
SUB
CODE
CODE
34
14
34
15
34
16
35
0
35
16
36
0
41
12
41
13
41
14
41
15
41
16
41
21
41
22
41
23
41
24
41
25
41
26
42
12
42
13
DESCRIPTION
EEPROM, Power Off
Block checksum
EEPROM, Diagnostic
Queue Block Checksum
EEPROM, Real Time
Block Checksum
Power interruption
(Code set after power restored)
Real Time EEPROM
Write Interruption
Hardware/Software
not compatible
Open or short to ground,
A solenoid circuit
Open or short to ground,
B solenoid circuit
Open or short to ground,
C solenoid circuit
Open or short to ground,
D solenoid circuit
Open or short to ground,
E solenoid circuit
Open or short to ground,
F solenoid circuit
Open or short to ground,
G solenoid circuit
Open or short to ground,
H solenoid circuit
Open or short to ground,
J solenoid circuit
Open or short to ground,
K solenoid circuit
Open or short to ground,
N solenoid circuit
Short to battery, A
solenoid circuit
Short to battery, B
solenoid circuit
8-14
CHECK
INHIBITED
TRANS
OPERATION
LIGHT
DESCRIPTION
Yes
Use previous location,
or factory calibration
and reset adaptive
Yes
Use previous location,
or clear diagnostic queue
Yes
CT, SOL OFF
(Hydraulic default)
No
NONE (Hydraulic
default during
interruption)
Yes
CT, SOL OFF
(Hydraulic default)
Yes
CT, SOL OFF
(Hydraulic default)
Yes
CT, SOL OFF
(Hydraulic default)
Yes
CT, SOL OFF
(Hydraulic default)
Yes
CT. SOL OFF
(Hydraulic default)
Yes
CT, SOL OFF
(Hydraulic default)
Yes
CT, SOL OFF
(Hydraulic default)
No
Lock-up inhibited
Yes
CT, SOL OFF
(Hydraulic default)
No
Retarder allowed,
differential lock inhibited
No
Low and 1st inhibited
No
K solenoid
operation inhibited
No
Low and 1st inhibited
Yes
CT, Lock in a range
Yes
CT, Lock in a range

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3-45

Table of Contents