Eaton Fuller Semi-Automatic Transmission Fault Codes; Light Bulb Data - PREVOST H3-41 Manual

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

• Observe the sequence of flashes on the indicator lights and record the codes. A one or two second
second pause separates each stored code and the sequence automatically repeats after all codes have
been flashed.
Refer to Eaton Fuller Troubleshooting Guide (TRTS-0050).

Eaton Fuller Semi-Automatic Transmission Fault Codes

Code
Description
11
System controller
12
Transmission ECU
13
Power connect relay
coil
14
Shift lever
15
Shift lever data link
16
Eaton proprietary link
(EPL)
17
Start enable realy Coil
31
Engine brake relay coil
33
Battery voltage supply

LIGHT BULB DATA

Code
Description
35
Engine control failure
41
Range failed to
engage
43
Range solenoid valve
44
Inertia brake solenoid
coil
51
Rail select sensor
52
Gear select sensor
53
Reverse ball switch
56
Input shaft speed
sensor
57
Main shaft speed
sensor
LIGHT BULB DATA
8-25
TECHNICAL INFORMATION
Code
Description
58
Output shaft speed
sensor
61
Rail select motor
63
Gear select motor
65
Low motor voltage
71
Stuck engaged
72
Failed to select rail
73
Failed to engage gear
74
Failed to syncronize
initial engagement
83
Shift lever missing

Hide quick links: