PREVOST H3-41 Manual page 103

Hide thumbs Also See for H3-41:
Table of Contents

Advertisement

MAIN
SUB
CODE
CODE
23
14
Secondary Shift Selector
or RSI Link Fault
23
15
Secondary Shift Selector
Mode Function Fault
24
12
Sump oil temperature, cold
24
23
Sump oil temperature, hot
25
0
Output speed reasonableness
test, detected at 0 speed, (L)
25
11
Output speed reasonableness
test, detected at 0 speed, (1st)
25
22
Output speed reasonableness
test, detected at 0 speed 2nd
25
33
Output speed reasonableness
test, detected at 0 speed, 3rd
25
44
Output speed reasonableness
test, detected at 0 speed, 4th
25
55
Output speed reasonableness
test, detected at 0 speed, 5th
25
66
Output speed reasonableness
test, detected at 0 speed, 6th
25
77
Output speed reasonableness
test, detected at 0 speed, R
32
0
C3 pressure switch open,
L range
32
33
C3 pressure switch open,
3rd range
32
55
C3 pressure switch open,
5th range
32
77
C3 pressure switch open,
R range
33
12
Sump oil temperature
sensor, low
33
23
Sump oil temperature
sensor, high
34
12
EEPROM, factory cal.
compatibility number wrong
34
13
EEPROM, factory
calibration block checksum
DESCRIPTION
8-13
TECHNICAL INFORMATION
CHECK
INHIBITED
TRANS
OPERATION
LIGHT
DESCRIPTION
No
Hold in last valid direction
No
Mode change not
permitted
Yes
CT
No
No upshifts above a
calibration range
Yes
CT, Lock in current
range (L)
Yes
CT, Lock in current
range (1 st)
Yes
CT, Lock in current
range (2nd)
Yes
CT, Lock in current
range (3rd)
Yes
CT, Lock in current
range (4th)
Yes
CT, Lock in current
range (5th)
Yes
CT, Lock in current
range (6th)
Yes
CT, Lock in current
range (R)
Yes
CT, Lock in current
range (L)
Yes
CT, Lock in current
range (3rd)
Yes
CT, Lock in current
range (5th)
Yes
CT, Lock in current
range (R)
No
Use default value of
200ø F (93ø C)
No
Use default value of
200ø F (93ø C)
Yes
CT, SOL OFF
(Hydraulic default)
Yes
CT, SOL OFF
(Hydraulic default)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H3-45

Table of Contents