TECHNICAL INFORMATION
Electrical connection is made through a 35 pin
plug
Maintenance: .................................................. none
Solenoid Control Valve Technical Data
Voltage:....................................24 (+4.8, -2.4) volts
Current:.............................................................. DC
Rated current:........................................ 1.65 amps
Protection system according to DIN 40050
Maximum service pressure:........10 bars (145 psi)
Thermal operating range:
..................................... -40 to 176 °F(-40 to 80 °C)
Electrical connector: ........................894 601 010 2
Installation:
Maximum pipe length between
solenoid control valve and brake cylinder is 5' (1,5

WATER HEATER TECHNICAL DATA

Heating capacity
Heating output
Fuel type
Fuel consumption
Rated voltage
Electricity consumption 55 watts

DDEC IV DIAGNOSTIC CODES

To Read Codes:
Plug a diagnostic data reader into the receptacle located on the side panel of the L.H. control panel or
momentarily depress the STOP ENGINE OVERRIDE switch, located on the L.H. lower control panel, with
the ignition ON, the engine idling or engine shut-off. Active codes will be flashed on the STOP ENGINE
indicator light, located on the central dashboard, followed by the inactive codes being flashed on the CHECK
ENGINE indicator light located on the central dashboard. The cycle is repeated until the operator depresses
the STOP ENGINE OVERRIDE switch. For example; a code "43" consists of four flashes, followed by a
short pause, then another three flashes in quick succession. The following table is a list of the diagnostic
codes.
DDEC
Code
Number
(Flashed)
11
Variable speed governor sensor
Espar D12W
12 kW
41,000 Btu/hr
Same as engine
1,75 U.S. qts (1,65 L/hr)
24 volts
DESCRIPTION
m); pipe diameter is 3/8" (10 mm) venting
downward at an angle of 15° on the vertical
plane.
Maintenance:...................................................none
Sensor Technical Data
Two-core screened cable: ..........AWG 18 (1 mm
Force needed to tear out lead: .......11.2 lbs (50 N)
Force needed to pull off shrink-fitted tube:
.........................................................11.2 lbs (50 N)
Protection system according to DIN 40050
Thermal operating range:
.................................... -40 to 176 °F (-40 to 80 °C)
Webasto DBW 2010 Webasto DBW 2020
13 kW
45 000 Btu/hr
Same as engine
1,58 U.S. qts (1,50 L/hr)
24 volts
60 watts
DDEC
Code
Number
(Flashed)
12
Variable speed governor sensor
8-6
23,3 kw
80 000 Btu/hr
Same as engine
3,17 U.S. qts (3,00 L/hr)
24 volts
120 watts
DESCRIPTION