Operating conditions: Process

10.7.1
Process temperature range
Note!
• The following process temperature ranges only apply for standard applications outside hazardous areas.
• Regulations for use in hazardous areas are provided in the Supplementary Documentation XA389F/00.
With compact housing
The following diagram applies to:
• Rod and rope version
• Insulation: PTFE, PFA, FEP
T
a
T
P
–80
–60
–80/
–25
T
: Ambient temperature
a
T
: Process temperature
P
Note!
• Restriction to T
–40 °C for polyester housing F16.
a
• If additional option B is selected (free from paint-wetting impairment substances), the minimum
ambient temperature T
is –40 °C. (Only relevant for FTI51!)
a
T
a
°C
80
60
40
20
0
0
20
40
60
–40 –20
–20
–40
–40/
–40
+20/
–60
–50
Technical data
+80/
+70
80
100
120
140
160 180
L00-FMI5xxxx-05-05-xx-xx-013
+200/
+38
T
P
°C
200
85