3. Set RS-232 Configuration parameters to enable communication with the display that is
connected to the acceptor (or any other device with an RS-232 port).
4. Configure the external device commands as follows:
▪
Enter a device command (for example, turn POWER OFF).
▪
Enter the command description (for example, Turn Display Off).
▪
Select a trigger from the drop-down box to carry out the command (5V On, 5V Off,
Sync/Clock, No Sync/No Clock).
▪
Enter a delay time, if required.
▪
Check Hex for Hex command format, if required.
▪
Check Enable to enable the command.
5. Click Add.
6. You can:
▪
Click Delete to delete the command.
▪
Click Test to test the command.
▪
Change any of the command configurations.
▪
Enable or disable the command.
Commands are sent to the display via
VP-427X1 – Using Embedded Web Pages
Figure 31: RS-232 Device Configuration Parameters
Figure 32: RS-232 Page – Creating a Command
Figure 33: RS-232 Page – Command Added
VP-427X1
RS-232 port.
Kramer Electronics Ltd.
39