Fault Diagnosis - Stanley 0753 MKII Instruction And Service Manual

Repetition tool for speed rivets
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
E N G L I S H

8. FAULT DIAGNOSIS

SYMPTOM
Tool will not place fas-
tener
'Mandrel Slip' - jaws will
not grip mandrel
Jaws will not release
mandrel
Fasteners will not feed
through nose jaws
Excessive tail jaw wear
Feeding more than one
fastener at a time
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.
30
POSSIBLE CAUSE
Low air pressure.
Lack of lubrication.
High broach load.
Check for correct size mandrel.
Worn or broken tail jaws.
Tail jaws switched off.
Air in hydraulic system.
Worn or dirty tail jaws.
' Insufficient air pressure/volume.
' Tail jaw switch inoperable.
' Air leaks to tail jaws.
Mandrel broken and not reaching tail jaws. Replace mandrel
Defective non-return valve.
Dirty tail jaws or jaw housing.
Faulty tail jaw switch.
Tail jaws not switched on.
Worn tail jaws.
Cursor orientation incorrect.
Incorrect cursor
Incorrect nose jaws.
Mandrel follower spring not fitted.
Incorrect gap between fastener head
and nose jaws when loaded.
Cursor sticking.
Weak outer spring around cursor.
Incorrect mandrel follower spring fitted. Fit correct mandrel follower spring
High broach load.
Mandrel slip.
Incorrect gap between fastener head
and nose jaws when loaded
O R I G I N A L I N S T R U C T I O N
REMEDY
Increase air pressure
Lubricate tool at air inlet point
Check fastener grip and applica-tion hole
size
New tail jaws
Switch on tail jaws
See 'Priming Procedure'
Clean or renew as necessary
Increase air pressure/volume
Replace switch
Renew 'O' rings on piston 8
Replace non-return valve
Clean and lubricate
Replace 'O' rings
Switch on tail jaws
Renew tail jaws
Refit, ensuring correct orientation
Fit correct cursor
Fit correct nose jaws
Fit correct mandrel follower spring
Set gap to 1.5mm - 3mm (1/16
See 'Loading the Tool'
Clean and oil cursor
Renew cursor
Check application hole size and thickness
and fastener grip capa-bility
Check as for 'Mandrel Slip' , stage 2
Set gap to 1.5mm - 3mm (1/16
See 'Loading the Tool' on page
PAGE REF.
29
- 1/8
)
"
"
13
- 1/8
)
"
"
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

075300753107532

Table of Contents