NPN/PNP switch function
The number of stock items can be reduced.
Select
NPN or PNP
NPN
Analog output of 0 to 10 V is
also available.
1 to 5 V
Voltage output
0 to 10 V
Current output
4 to 20 mA

Convenient functions

Copy function
The set values of
the monitor can
be copied to up to
10 monitors
Source of
simultaneously.
copy
Security code
The key locking function
keeps unauthorized
persons from tampering
with the settings.
External input function
The accumulated value, peak value, and bottom value can be reset remotely.
Functions
(EFor details, refer to pages 26 to 28.)
¡Output operation
¡FUNC output switching function
¡Simple setting mode
¡Selectable analog output function
¡Display color
¡External input function
¡Delay time setting
¡Forced output function
¡Digital filter setting
¡Accumulated value hold
Mounting
Bracket configuration allows for mounting in four orientations.
Bracket A
Mounting
example
Bracket B
Mounting
example
3-Screen Display
PNP
Switchable
Fixed
1 unit
2 units
Power saving function
Power consumption is reduced by turning off the monitor.
Current consumption *
Reduction rate *
1
25 mA or less
Approx. 50% reduction
*1 During normal operation *2 In power saving mode
Digital Flow Monitor
Input range selection (for Pressure/Flow rate)
The displayed value to the sensor input can be set as required.
(Voltage input: 1 to 5 V/Current input: 4 to 20 mA)
Pressure switch/Flow switch can be displayed.
B
A is displayed for 1 V (or 4 mA).
B is displayed for 5 V (or 20 mA).
Display
The range can be set as required.
A
Voltage input 1 V
5 V
Current input 4 mA 20 mA
Pressure Sensor for General Fluids/PSE570
1000
Display
Voltage input
Compact & Lightweight
Compact: Max. 6 mm shorter
Lightweight: Max. 5 g lighter (30 g / 25 g)
10 units
PFG300
2
PFM300
¡Peak/Bottom value display
¡Setting of a security code
¡Key-lock function
¡Reset to the default settings
¡Display with zero cut-off setting
Mountable side by side without clearance
One opening!
· Reduced panel fitting labor
· Space saving
PFG300
PSE570
PSE573
–100
PSE574
0
1 V
5 V
Set A and B to the values shown
in the table above.
6
25
mm
31
mm
¡Selection of the display on the sub screen
¡Analog output free range function
¡Error display function
¡Copy function
¡Selection of power saving mode