PF2MC7(-L)
Flow Range
Model
–100 L/min
5 L/min
PF2MC7501(-L)
5 L/min
–25 L/min
10 L/min
PF2MC7102(-L)
10 L/min
–50 L/min
PF2MC7202(-L)
–100 L/min
Analog Output
Flow/Analog Output
0 L/min
Voltage output (1 to 5 V) *
1
Current output *
1
0 L/min
Voltage output (0 to 10 V) *
1, 3
*1 Analog output accuracy is within ±3% F.S.
*2 A and C will change according to the setting of the zero cut function.
*3 The analog output current from the connected equipment
should be 20 μA or less when selecting 0 to 10 V. When more
than 20 μA current flows, it is possible that the accuracy is not
satisfied below 0.5 V.
* The min. value of the rated flow range will change according to
the setting of the zero cut function.
Model
Min. value of the rated flow range Max. value of the rated flow range
PF2MC7501(-L)
5 L/min
PF2MC7102(-L)
10 L/min
PF2MC7202(-L)
20 L/min
Pressure Loss (Reference Data)
PF2MC7501(-L) (for 500 L/min)
50
40
Supply pressure
30
200 kPa
20
Supply pressure
400 kPa
10
0
0
100
200
300
Flow [L/min]
IN Side Straight Piping Length and Accuracy (Reference Data)
• The piping on the IN side must have a straight section of piping with a length of 8 cm or more.
If a straight section of piping is not installed, the accuracy can vary by approximately ±2% F.S.
* The "straight section" refers to a section of piping without any bends or rapid changes in the cross
sectional area.
• When the PF2MC7501 or 7102 is connected to tubing, use a tube I.D. 9 mm or more just before
the product. The accuracy can vary by approximately ±2% F.S. when such tubing is not used.
Straight
piping length
IN
13
Series
0 L/min
200 L/min
20 L/min
20 L/min
A *
2
B
1 V
1.04 V
5 V
4 mA
4.16 mA
20 mA
C *
2
D
0 V
0.1 V
10 V
500 L/min
1000 L/min
2000 L/min
PF2MC7102(-L) (for 1000 L/min)
50
40
30
20
10
0
400
500
0
OUT
Flow range
500 L/min
500 L/min
525 L/min
525 L/min
Rated flow range
B
A
0
Min. value of the
Max. value of the
rated flow range
rated flow range
Voltage output (1 to 5 V)/
Current output (4 to 20 mA)
Supply pressure
200 kPa
Supply pressure
400 kPa
200
400
600
800
1000
Flow [L/min]
1000 L/min
1000 L/min
1050 L/min
1050 L/min
Set point range
D
C
0
Flow
Min. value of the
rated flow range
Voltage output (0 to 10 V)
PF2MC7202(-L) (for 2000 L/min)
50
Supply pressure
40
200 kPa
30
Supply pressure
400 kPa
20
10
0
400
800
0
Flow [L/min]
±6
±5
±4
±3
±2
±1
±0
0
1
2
3
4
Straight piping length [cm]
2000 L/min
2000 L/min
2100 L/min
2100 L/min
Display range
Max. value of the
Flow
rated flow range
1200
1600
2000
5
6
7
8
9
10
Need help?