PF2MC7(-L)
Specifications
Model
Applicable fluid
Fluid
Fluid temperature range
Detection method
Rated flow range
Instantaneous flow
Set point
range
Accumulated flow
Flow
Instantaneous flow
Smallest settable
increment
Accumulated flow
Accumulated volume per pulse
(Pulse width = 50 ms)
Accumulated value hold function *
Rated pressure range
Proof pressure
Pressure
Pressure loss
Pressure characteristics *
When used as a
Power
switch output device
supply
When used as an
voltage
Electrical
IO-Link device
Current consumption
Protection
Display accuracy
Analog output accuracy
Accuracy
Repeatability
Temperature characteristics
Output type
Output mode
Switch operation
Max. load current
Switch output
Max. applied voltage
Internal voltage drop
Digital filter *
3
Delay time *
4
Hysteresis *
5
Protection
Output type
Analog output *
6
Voltage output
Impedance
Current output
Response time *
External input
External input *
9
Input mode
Reference condition *
Instantaneous flow
Unit *
11
Accumulated flow
Instantaneous flow
Display
range
Accumulated flow
Instantaneous flow
Min. display
Display
unit
Accumulated flow
Display type
Display
Indicator LED
Enclosure
Withstand voltage
Environmental
Insulation resistance
resistance
Operating temperature range
Operating humidity range
Standards
Piping specification
Main materials of parts in contact with fluid
Piping
specification
Weight
Lead wire
Bracket
11
Series
PF2MC7501
(Air quality grade is JIS 8392-1 1.1.2 to 1.6.2, ISO 8573-1 1.1.2 to 1.6.2.)
5 to 500 L/min
5 to 525 L/min
1 L/pulse
1
2
Select from Hysteresis, Window comparator, Accumulated output,
Accumulated pulse output, Error output, or Switch output OFF modes.
Voltage output: 1 to 5 V (0 to 10 V can be selected, only when the power supply voltage is 24 VDC) *
Max. load impedance: 600 W at power supply voltage of 24 V, 300 W at power supply voltage of 12 V
8
Input voltage: 0.4 V or less (Reed or Solid state) for 30 ms or longer
10
–25 to 525 L/min
(Displays [0] when value is within the –4 to 4 L/min range)
LCD, 3-screen display (Main screen/Sub screen)
Main screen: Red/Green, Sub screen: White
Main screen: 4 digits, 7 segments, Sub screen: 9 digits, 11 segments
Display values updated 5 times per second
2 MW or more (50 VDC measured via megohmmeter) between external terminals and housing
Operating: 0 to 50°C, Stored: –10 to 60°C (No condensation or freezing)
Rc thread
NPT thread
G thread
For flow switch precautions and specific product precautions,
refer to the "Operation Manual" on the SMC website.
PF2MC7102
Dry air, N
0 to 50°C
Thermal type
10 to 1000 L/min
10 to 1050 L/min
0 to 999,999,990 L
1 L/min
10 L
Intervals of 2 or 5 minutes can be selected.
0 to 0.8 MPa
1.2 MPa
Refer to the "Pressure Loss" graph.
±5% F.S. (25°C standard) F.S. (0 to 0.8 MPa, 0.6 MPa standard)
12 to 24 VDC ±10%, Ripple (p-p) 10% or less
18 to 30 VDC ±10%
55 mA or less
Polarity protection
±3% F.S.
±3% F.S.
±1% F.S. (±2% F.S. when the response time is set to 0.05 s)
±5% F.S. (0 to 50°C, 25°C standard)
Select from NPN or PNP open collector output.
Select from Normal or Reversed output.
80 mA
28 V (NPN output)
1.5 V or less (at load current of 80 mA)
Select from 0.05 s, 0.1 s, 0.5 s, 1.0 s, 2.0 s, or 5.0 s.
Variable from 0 to 60 s/0.01 s increments
Variable from 0
Short circuit protection
Current output: 4 to 20 mA
Output impedance: Approx. 1 kW
Linked to the set value of the digital filter
Accumulated value external reset, Peak/Bottom value reset
Select from Standard condition (STD) or Normal condition (NOR).
L/min, cfm (ft
L, ft
3
–50 to 1050 L/min
(Displays [0] when value is within the –9 to 9 L/min range)
0 to 999,999,999 L
1 L/min
10 L
LCD
LED ON when switch output is ON (OUT1/OUT2: Orange)
IP65
250 VAC for 1 min between external terminals and housing
Operating/Stored: 35 to 85% R.H. (No condensation or freezing)
CE marking (EMC Directive, RoHS Directive)
Rc1/2, NPT1/2, G1/2
Stainless steel 304, PPS, Aluminum alloy, HNBR, Si, Au, GE4F
160 g
170 g
+80 g
+25 g
PF2MC7202
2
20 to 2000 L/min
20 to 2100 L/min
10 L/pulse
3
/min)
–100 to 2100 L/min
(Displays [0] when value is within the –19 to 19 L/min range)
Rc3/4, NPT3/4, G3/4
240 g
245 g
+30 g