PS220 Configuration & Operation Guide
GROUP 5
DIAGNOSTICS
ON-TIME COUNTER
5.01
RUN-TIME COUNTER
5.02
FAN ON-TIME COUNTER
5.04
TIME FROM POWER-UP
5.09
INVERTER TEMPERATURE
5.11
DIAGNOSTIC WORD 3
5.22
MAIN FAN SERVICE COUNTER
5.41
AUX. FAN SERVICE COUNTER
5.42
CONTROL & STATUS WORDS
GROUP 6
MAIN CONTROL WORD
6.01
APPLICATION CONTROL WORD
6.02
FBA A TRANSPARENT CONTROL
6.03
WORD
FBA B TRANSPARENT CONTROL
6.04
WORD
EFBA TRANSPARENT CONTROL WORD
6.05
MAIN STATUS WORD
6.11
DRIVE STATUS WORD 1
6.16
DRIVE STATUS WORD 2
6.17
START INHIBIT STATUS WORD
6.18
SPEED CONTROL STATUS WORD
6.19
CONSTANT SPEED STATUS WORD
6.20
DRIVE STATUS WORD 3
6.21
DRIVE INHIBIT STATUS WORD 2
6.25
VARIOUS ACS880 CONTROL AND
6.29-6.101
STATUS WORDS
PUMP STATUS
6.200
PUMP WATER FEATURE CW
6.201
PUMP WATER FEATURE SW
6.202
PUMPSMART ALARM WORD 1
6.203
PUMPSMART ALARM WORD 2
6.204
265 PS220
DESCRIPTION
On-time counter. The counter runs when the drive is powered. (0-65535 days)
Motor run-time counter. The counter runs when the inverter modulates. (0-65535 days)
Running time of the drive cooling fan. Can be reset from the control panel by keeping Reset
depressed for over 3 seconds. (0-65535 days)
500-microsecond ticks elapsed since the last boot of the control unit. (0-4294967295)
Estimated drive temperature in percent of fault limit. The actual trip temperature varies
according to the type of the drive. (40.0-160.0%)
• 0.0% = 0 °C (32 °F)
• 94% approx. = Warning limit
• 100.0% = Fault limit
Diagnostic word 3.
Displays the age of the main cooling fan as a percentage of its estimated lifetime. The
estimate is based on the duty, operating conditions and other operating parameters of the
fan. When the counter reaches 100%, a warning is generated. Can be reset from the
control panel by keeping Reset depressed for over 3 seconds. (0-150%)
Displays the age of the auxiliary cooling fan as a percentage of its estimated lifetime. The
estimate is based on the duty, operating conditions and other operating parameters of the
fan. When the counter reaches 100%, a warning is generated. Can be reset from the
control panel by keeping Reset depressed for over 3 seconds. (0-150%)
DESCRIPTION
The main 16 bit control word of the drive. The bit assignments of the word are as described
in the ACS880 Firmware Manual. This parameter is read-only in Hex.
Reference the ABB ACS880 Firmware Manual for parameter definition.
Displays the unaltered control word received from the PLC through fieldbus adapter A when
a transparent communication profile is selected. This parameter is read-only.
(00000000h-FFFFFFFFh)
Displays the unaltered control word received from the PLC through fieldbus adapter B when
a transparent communication profile is selected. See section Control word and Status word
in the ACS880 Firmware Manual. This parameter is read-only. (00000000h-FFFFFFFFh)
Displays the unaltered control word received from the PLC through the embedded
fieldbus interface when a transparent communication profile is selected in parameter
58.25 Control profile. See section The Transparent profile in the ACS880 Firmware Manual.
This parameter is read-only. (00000000h-FFFFFFFFh)
Main 16 bit status word of the drive. Parameter is read-only. (0000h-FFFFh)
Drive status word 1. This parameter is read-only. See the ACS880 Firmware Manual for bit
assignment.
Drive status word 2. This parameter is read-only. See the ACS880 Firmware Manual for bit
assignment.
Start inhibit status word. This word specifies the source of the inhibiting condition that is
preventing the drive from starting. After the condition is removed, the start command must
be cycled. See bit-specific notes. See also parameter 06.25 Drive inhibit status word 2, and
06.16 Drive status word 1, bit 1. This parameter is read-only. See the ACS880 Firmware
Manual for bit assignment. (0000h-FFFFh)
This parameter is read-only. See the ACS880 Firmware Manual for bit assignment.
(0000h-FFFFh)
Constant speed/frequency status word. Indicates which constant speed or frequency is
active (if any). See also parameter 06.19 Speed control status word, bit 7, and section
Constant speeds/frequencies (page 43). This parameter is read-only. See the ACS880
Firmware Manual for bit assignment. (0000h-FFFFh)
This parameter is read-only. See the ACS880 Firmware Manual for bit assignment.
(0000h-FFFFh)
This word specifies the source of the inhibiting condition that is preventing the drive from
starting. After the condition is removed, the start command must be cycled. See bit-specific
notes. See also parameter 06.18 Start inhibit status word, and 06.16 Drive status word 1, bit
1. This parameter is read-only. See the ACS880 Firmware Manual for bit assignment.
(0000h-FFFFh)
Reference the ABB ACS880 Firmware Manual for parameter definition.
The 16 bit Pump Status Word for the PS220
The 16 bit PS220 Control Word for the PumpSmart water functions
The 16 bit PS220 Status Word for the PumpSmart water functions
The 16 bit PS220 Alarm word 1 (16 bit)
The 16 bit PS220 Alarm word 2 (16 bit)
Scaling
1=1 day
1=1 day
1=1 day
1=1
1=1%
1=1
1=1%
1=1%
Scaling
HEX
HEX
HEX
HEX
HEX
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
—
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS
BINARY ACTUAL
BITS