Safety Considerations; Introduction; Receiving And Installation; Check Equipment - Carrier Infinity 48XL Installation Instructions Manual

15 seer single packaged air condotioner and gas furnace system with puron (r-410a) refrigerant
Hide thumbs Also See for Infinity 48XL:
Table of Contents

Advertisement

SAFETY
CONSIDERATIONS
Installation
and servicing
of this equipment
can be hazardous
due
to mechanical
and
electrical
components.
Only
trained
and
qualified
personnel
should install, repair, or service
this equipment.
Untrained
personnel
can perform
basic
maintenance
flmctions,
such as cleaning
and replacing
air filters. All other operations
must
be performed
by trained service
personnel.
When working
on this
equipment,
observe
precautions
in the literature,
on tags, and on
labels
attached
to or shipped
with
the unit
and other
safety
precautions
that may apply.
Follow
all safety
codes.
Installation
must
be in compliance
with
local and national
building
codes.
Wear safety
glasses,
protective
clothing,
and work
gloves.
Have fire extinguisher
available.
Read
these instructions
thoroughly
and follow
all warnings
or cautions
included
in literature
and
attached
to the unit.
Recognize
safety information.
This is the safety-alert
symbol
/_.
When you see this symbol
on the unit and in instructions
or manu-
als, be alert to the potential
for personal
iniury.
Understand
these
signal
words:
DANGER,
WARNING,
and
CAUTION.
These
words
are used with the safety-alert
symbol.
DANGER
identifies
the most serious hazards
which
will result in severe personal
iniury
or death.
WARNING
signifies
hazards
which
could
result
in per-
sonal iniury or death. CAUTION
is used to identify
unsafe
practic-
es which
may result in minor personal
injury or product
and prop-
erty damage.
NOTE
is used to highlight
suggestions
which
will
result in enhanced
installation,
reliability,
or operation.
Always
install furnace
to operate
within
the intended
temperature
rise range with a duct system
which has an external
static pressure
within the allowable
range, as specified
in "Indoor
Airflow
Adjust-
ments"
section of these instructions.
See furnace rating
plate.
ELECTRICALSHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury or death.
Before
installing
or servicing
system,
always
turn off main
power
to system
and tag disconnect.
There
may be more
than one disconnect
switch. Turn off accessory
heater power
switch
if applicable.
UNIT
OPERATION
AND SAFETY
HAZARD
Failure
to follow
this
warning
could
result
in personal
iniury or equipment
damage.
Puron
(R-410A)
systems
operate
at higher
pressures
than
standard
R-22
systems.
DO
NOT
use
R-22
service
equipment
or components
on Puron (R-410A)
equipment.
Ensure
service equipment
is rated for Puron (R-410A).
INTRODUCTION
The 48XL
packaged
unit
is a fully
self-contained
combination
Category
I gas heating/electric
air conditioner
designed
for outdoor
installation
(See
Fig.
1).
Standard
units
are
shipped
in
a
horizontal-discharge
configuration
for
installation
on
a
ground-level
slab or directly
on the ground
if local codes permit.
Standard
units can be converted
to downflow
(vertical)
discharge
configurations
for rooftop
applications.
Models
with
an N in the fifth position
of the model
number
are
dedicated
Low
NOx
units
designed
for
California
installations.
These
models
meet
the California
maximum
oxides
of nitrogen
(NOx)
emissions
requirements
of 40 nanograms/joule
or less as
shipped
from
the factory
and must be installed
in California
Air
Quality
Management
Districts
or any
other
regions
in North
America
where a Low NOx rule exists.
NOTE:
Low
NOx
requirements
apply
only
to
natural
gas
installations.
RECEIVING
AND INSTALLATION
Check Equipment
IDENTIFY
UNIT
The unit model
number
and serial number
are printed
on the unit
informative
plate. Check this information
against shipping
papers.
INSPECT
SHIPMENT
Inspect
for shipping
damage
while unit is still on shipping
pallet. If
unit appears
to be damaged
or is torn loose from
its anchorage,
have
it examined
by transportation
inspectors
before
removal.
Forward
claim
papers
directly
to
transportation
company.
Manufacturer
is not responsible
for any damage
incurred
in transit.
Check
all items
against
shipping
list.
Immediately
notify
the
nearest
Carrier
office
if any item
is missing.
To prevent
loss or
damage,
leave all parts in original
packages
until installation.
Provide
Unit Support
For
hurricane
tie downs,
contact
distributor
for details
and PE
(Professional
Engineering)
Certificate,
if required.
ROOF
CURB
Install
accessory
roof curt) in accordance
with instructions
shipped
with curt) (See Fig. 4). Install
insulation,
cant strips, roofing,
and
flashing.
Ductwork
must be attached
to curb.
IMPORTANT:
The gasketing
of the
unit to the roof curt) is
critical
for a water
tight seal.
Install
gasketing
material
supplied
with the roof curt). Improperly
applied
gasketing
also can result in
air leaks and poor unit performance.
Curb should be level to within
1/4 in. (6.35 m) (See Fig. 2). This is
necessary
for unit drain
to function
properly.
Refer
to accessory
roof
curt)
installation
instructions
for additional
information
as
required.
A-B
1/4 (6.35)
MAXIMUM
ALLOWABLE
DIFFERENCE
in. (ram)
B-C
A-C
1/4
(6.35)
1/4
(6.35)
A07925
Fig. 2 - Unit Leveling
Tolerances
SLAB MOUNT
Place the unit on a solid, level concrete
pad that is a minimum
of 4
in. (102 mm)
thick
with
2 in. (51 mm)
above
grade.
The slat)
should
extend
approximately
2 in. (51 mm) beyond
the casing
on
all 4 sides of the unit (See Fig. 3). Do not secure the unit to the slat)
except when required
by local codes.
2"
_
(50.Smm)
RETURr
SUPPLY
lUll
.,_
lY/i_
\
\'\1
.,_
dill
m_
_E_
dlII
III1| OPENIN,_
i
_,
f--_OPENING
1111
IIII|
tlil _
_z_
(
't [
_I II
IIIII
Ill[
I_J'/_
_
_ II
jl II
IIIII
Ill| IIll _ <s' _
I! ,I
tlii
_
Hiv-'_ \ -- JbJ/ ....
illl
IIIII
N
I/
"_
//I
II II
IIIII
_'_
A'
)
/_
II II
IIIII
N?',.q
/
//
II II
#--
-2=_--__-----_/
.
j,
.
/
/
EVAR
COIL
COND.
COIL
A07926
Fig. 3 - Slab Mounting
Detail
GROUND
MOUNT
The unit may be installed
either on a slab or placed directly
on the
ground
if local
codes
permit.
Place
the
unit
on level
ground
prepared
with gravel
for condensate
discharge.