Provide Clearances; Rig And Place Unit - Carrier Infinity 48XL Installation Instructions Manual

15 seer single packaged air condotioner and gas furnace system with puron (r-410a) refrigerant
Hide thumbs Also See for Infinity 48XL:
Table of Contents

Advertisement

UNIT
SIZE
NOMINAL COOLING
CAPACITY
(ton)
NOMINAL HEATING CAPACITY
(Btu)
OPERATING
WEIGHT
(Ib)
(kg)
COMPRESSORS
Quantity
REFRIGERANT:
PURON (R-410A)
Quantity
(Ib)
(kg)
REFRIGERANT
METERING
DEVICE
Size
Part Number
OUTDOOR
FAN
Nominal Cfm
Diameter
(in.)
(mm)
Motor Hp (Rpm)
OUTDOOR
COIL
Rows...Fins/in,
Face Area (sq ft)
INDOOR COIL
Rows...Fins/in,
Face Area (sq ft)
INDOOR FAN
Nominal Airflow (Cfm)
Comfort
Efficiency
Max
Furnace
(gas ht.) airflow-Low
Stage
Furnace
(gas ht.) airflow-High
Stage
Size (in.)
(ram)
Motor HP (RPM)
FURNACE SECTION*
Burner Orifice No. (Qty._Drill
Size)
Natural Gas
HIGH-PRESSURE
SWITCH
(peig)
Cut-out
Reset (Auto)
HIGH-PRESSURE
SWITCH
2 (peig)
(Compressor
Solenoid)
Cut-out
Reset (Auto)
LOSS-OF-CHARGE
/
LOW-PRESSURE
SWITCH
(Liquid Line) (psig)
Cut-out
Reset
(auto)
RETURN-AIR
FILTERS
Throwaway
(in.)1-
(ram)
Table
1--Physical
Data (Con't)
- Unit 48XL
048090
048115
060115
060130
4
4
5
5
90,000
115,000
115,000
130,000
521
521
572
572
236
236
259
259
048130
060090
4
5
130,000
90,000
521
572
236
259
2-Stage
Scroll
1
15.3
15.3
15.3
15.8
15.8
15.8
6.9
6.9
6.9
7.2
7.2
7.2
TXV
4Ton
4Ton
4Ton
5Ton
5Ton
5Ton
EA36YD 149
EA36YD 149
EA36YD 149
EA36YD 159
EA36YD 159
EA36YD 159
3300
3300
3300
3300
3300
3300
22
22
22
22
22
22
559
559
559
559
559
559
1/4 (1100)
1/4 (1100)
1/4 (1100)
1/3 (1110)
1/3 (1110)
1/3 (1110)
2...21
2...21
2...21
2...21
2...21
2...21
19.4
19.4
19.4
23.3
23.3
23.3
3...17
3...17
3...17
4...17
4...17
4...17
5.7
5.7
5.7
5.7
5.7
5.7
Variable
based on Comfort
Rollback(see
Userlnterfaceinstructionsfor
moreinformation).
1400
1400
1400
1750
1750
1600
1600
1600
2000
2000
1255
1875
11x10
279x254
3/4
845
1300
11x10
279x254
1
1215
1910
11x10
279x254
1
815
1385
11x10
279x254
3/4
1215
1885
11x10
279x254
3/4
1750
2000
1255
1920
11x10
279x254
1
3...38
3...33
3...31
3...38
3...33
3...31
670 ± 10
470 ± 25
565 ± 15
455 ± 15
23 ± 5
55 ± 5
24x36xl
610x914x25
*Based on altitude of 0 to 2000 ft (0 to 610 m).
1-Recommended
filter sizes for field-installed
air filter grilles mounted on the wall or ceiling of the conditioned
structure.
Required filter sizes shown are based on
the larger of the ARI (Air Conditioning
and Refrigeration
Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway
type or 450
ft/minute for high-capacity
type. Air filter pressure drop for non-standard
filters must not exceed 0.08 IN. W.C.
Rig and Place Unit
Rigging
and
handling
of
this
equipment
can
be
hazardous
for
many
reasons
due
to
the
installation
location
(roofs,
elevated
structures,
etc.).
Only
trained,
qualified
crane
operators
and
ground
support
staff
should
handle
and
install
this
equipment.
When
working
with
this
equipment,
observe
precautions
in
the
literature,
on tags,
stickers,
and
labels
attached
to
the
equipment,
and
any
other
safety
precautions
that
might
apply.
Training
for operators
of the
lifting
equipment
should
include,
but
not
be limited
to, the following:
1. Application
of the
lifter
to
the load,
and
adjustment
of the
lifts
to adapt
to various
sizes
or kinds
of loads.
2.
Instruction
in any
special
operation
or precaution.
3.
Condition
of the
load
as it relates
to operation
of the lifting
kit, such
as balance,
temperature,
etc.
Follow
all
applicable
safety
codes.
Wear
safety
shoes
and
work
gloves.
7
Provide Clearances
The
required
minimum
service
clearances
are
shown
in 5 and
6.
Adequate
ventilation
and
outdoor
air
must
be
provided.
The
outdoor
fan
draws
air
through
the
outdoor
coil
and
discharges
it
through
the
top
fan
grille.
Be
sure
that
the
fan
discharge
does
not
recirculate
to
the
outdoor
coil.
Do
not
locate
the
unit
in either
a
corner
or under
an overhead
obstruction.
The
minimum
clearance
under
a partial
overhang
(such
as a normal
house
overhang)
is 48
in.
above
the
unit
top.
The
maximum
horizontal
extension
of
a
partial
overhang
must
not
exceed
48 in. (1219
mm).
IMPORTANT:
Do
not
restrict
outdoor
airflow.
An
air restriction
at
either
the
outdoor-air
inlet
or
the
fan
discharge
may
be
detrimental
to compressor
life.
Do
not
place
the
unit
where
water,
ice,
or snow
from
an overhang
or roof
will
damage
or flood
the
unit.
Do
not
install
the
unit
on
carpeting
or
other
combustible
materials.
Slab-mounted
units
should
be at least
4 in. (102
mm)
above
the highest
expected
water
and
runoff
levels.
Do not
use unit
if it has been
under
water.