Carrier Infinity 48XL Installation Instructions Manual page 19

15 seer single packaged air condotioner and gas furnace system with puron (r-410a) refrigerant
Hide thumbs Also See for Infinity 48XL:
Table of Contents

Advertisement

o
O
O
O
OO
©
D
°°
{]
[E]
[
.a
O
UTILITY RELAY
*
UTILITY
SIGNAL
'_
OPEN
RELAY
* SUPPLIED
BY UTILITY
PROVIDER
O
•43ff]°
O0
0
d]]O
oo
@ IRcD
@
Lql_id
Ilne
So
lellold
@
Fig. 18 - 2-Stage
HP/AC
Control
Board
A05247
STATUS
CODE 21 - GAS HEATING
LOCKOUT
Control
will NOT
auto reset. Check
for mis-wired
gas valve
or
defective
control
(valve relay).
STATUS
CODE
22
ABNORMAL
FLAME-PROVING
SIGNAL
Flame
is proved
while
gas valve is de-energized.
Inducer
will run
until fault is cleared.
Check for leaky gas valve or stuck-open
gas
valve.
STATUS
CODE 23 - PRESSURE
SWITCH
DID NOT OPEN
Check
for obstructed
pressure
tubing
or pressure
switch
stuck
closed.
STATUS
CODE 24 - SECONDARY
VOLTAGE
FUSE
IS OPEN
Check for short circuit in secondary
voltage
(24VAC)
wiring.
STATUS
CODE
25
-
INVALID
MODEL
SELECTION
OR
SETUP
ERROR
Indicates
either
the model
plug
is missing
or incorrect.
If code
flashes
4 times
on
power-up,
control
is defaulting
to model
selection
stored in memory.
Check for proper
model
plug number
and resistance
values per wiring
diagram.
STATUS
CODE 31, 32 - PRESSURE
SWITCH
OR RELAY
DID
NOT CLOSE
OR REOPENED
Control
relay may be defective.
If open
longer
than five minutes,
inducer
shuts off for 15 minutes
before retry. If open during blower
on-delay
period,
blower
will come
on for the selected
blower
off-delay.
Check
for
excessive
wind,
restricted
vent,
defective
inducer
motor,
defective
pressure
switch,
lower
inducer
voltage
(230VAC),
inadequate
combustion
air
supply,
disconnected
or
obstructed
pressure
tubing,
or low
inlet gas pressure
(if LGPS
used).
STATUS
CODE 33 - LIMIT
CIRCUIT
FAULT
Indicates
a limit or flame rollout
switch
is open.
Blower
will run
for 4 minutes
or until open switch
remakes,
whichever
is longer.
If
open longer
than 3 minutes,
code changes
to lockout
13. If open
less than 3 minutes
status code 33 continues
to flash until blower
shuts off. Check
for loose blower
wheel,
restricted
vent, excessive
wind,
dirty
filter
or restricted
duct
system,
defective
switch
or
connections,
or inadequate
combustion
air supply
(flame
roll-out
switch
open).
STATUS
CODE 34 - IGNITION
PROVING
FAILURE
Control
will try three more times before lockout
14 occurs. If flame
signal lost during blower
on-delay
period,
blower
will come on for
the selected
blower
off-delay.
Check
for
oxide buildup
on flame
sensor
(clean with fine steel wool),
proper
flame sense microamps
(.5 microamps
D.C. min., 4.0-6.0
nominal),
manual
valve shutoff,
low
inlet
gas
pressure,
control
ground
continuity,
gas
valve
defective
or turned
off,
flame
sensor
must
not
be
grounded,
inadequate
flame carryover
or rough ignition,
or green/yellow
wire
must be connected
to unit sheet metal.
STATUS
CODE 41 - BLOWER
MOTOR
FAULT
Indicates
the blower
failed to reach 250 RPM or the blower
failed
to communicate
within
the prescribed
time limits. Thirty
seconds
after
being
turned
ON
or
ten
seconds
during
steady-state
operation.
STATUS
CODE 45 - CONTROL
CIRCUITRY
LOCKOUT
Auto reset after one hour lockout
due to gas valve relay stuck open,
flame sense circuit failure,
or software
check error. Reset power
to
clear lockout.
Replace
control if status code repeats.
E. HP/AC
Control
Troubleshooting
See
Table
4
for
HP/AC
control
board
status
codes
and
troubleshooting
information.
STATUS
CODE
53,
OUTDOOR
AIR
TEMPERATURE
SENSOR
FAULT
- DETAILED
DESCRIPTION
If an OAT sensor is found
at power-up,
input is constantly
checked
to be within
a valid temperature
range.
If sensor
is found
to be
open
or shorted
at any time after initial validation,
Status
Code 53
will be displayed
at amber STATUS
LED.
Check
for faults
in wiring
connecting
sensor
to OAT terminals.
Using
an Ohm meter, check resistance
of thermistor
for a short or
open condition.
19